| Sign In | Join Free | My insurersguide.com |
|
| Categories | IO LINK |
|---|---|
| Brand Name: | SUPERISYS |
| Model Number: | 16 channel digital input and output series |
| Certification: | ISO\FCC\ROSH |
| Place of Origin: | CHINA |
| MOQ: | one |
| Price: | Large quantity price negotiable |
| Payment Terms: | T/T, Western Union |
| Supply Ability: | 1000 per day |
| Delivery Time: | 1-2 work days |
| Stock: | In Stock |
| Description: | 16 channel digital input and output series |
| Product description: | IP67 protection class |
| I/O connection mode: | M12, 5pin hole holder, A code |
| Number of IO-Link ports: | 1x device |
| lO-Link deals with data length: | Two input bytes |
| Minimum cycle period: | 3 ms |
| Rated operational voltage: | 18…30V DC |
| Maximum load current (sensor): | 200 mA |
| Maximum load current (actuator): | 500 mA |
| Total current UI: | <1.6A |
| Total current UO: | <2.5A |
| IO-LINK RUN: | Red: communication interruption |
| PWR: | Yellow: the auxiliary power supply is not connected |
| I/O: | Red: port failure |
| Shell material: | PA6+GF |
| Shell color: | black |
| level of protection: | IP67, epoxy full potting |
| Boundary dimension: | 155mm x53mm x28.7mm |
| Weight: | 217g |
| Operating temperature: | -25°C...70°C |
| Storage/transport temperature: | 40°C...85°C |
| Operation humidity: | 5%...95% |
| Store/transport humidity: | 5%...95% |
| Operating atmospheric pressure: | 80KPa...106KPa |
| Store/transport atmospheric pressure: | 80KPa...106KPa |
| I/O port tightening torque: | M12:0.5Nm |
| Application environment: | In accordance with EN-61131 |
| Vibration measurement: | Comply with IEC60068-2 |
| Impact test: | Comply with IEC60068-27 |
| Free drop test: | Comply with IEC60068-32 |
| Electromagnetic compatibility (EMC): | Comply with IEC61000-4-2,-3,-4 |
| Authentication: | CE,RoHS |
| Mounting hole specification: | ∅4.3mm x 4 |
| IO LINK: | Point To Point Networking Standard |
IACM-DO16P-IOL-V,IOLINK Slave Station,Can Expand 16 Channels Digital Input And Output Series,
Product characteristics
Wide use, long life, high reliability:
Working voltage: 10-30VDC;
Output function: two lines normally open normally closed
With polarity, overload, short circuit protection
Protection level: IP67
Direct outlet type, connector type
Operating temperature -25°C-+70°C
Capacitor switch all series have high and low temperature resistance series
| Model | IACM-DO16P-IOL-V | IACM-DO16P-IOL-VR | IACM-DIO16P-IOL-V | IACM-DIO16P-IOL-VR |
| product description | IO-LINK slave module | |||
| 8 x ports | ||||
| IP67 protection rating | ||||
| I/O connection mode | M12, 5pin socket, code A | |||
| IO-Link slave station parameters | ||||
| Number of IO-Link ports | 1x Equipment | |||
| lO-Link Processes the data length | 2 Output bytes | Two input bytes, two output bytes | ||
| Minimum cycle | 3 ms | |||
| Input and output parameters | ||||
| Quantity of input and output | 16-Channel output | 16-Way Adaptive | ||
| Rated operational voltage | 18…30V DC | |||
| Maximum load Current (Sensor) | - | 200 mA | ||
| Maximum load current (sensor) | 2A | |||
| Total current UI | - | <1.6A | ||
| Total current UO | <12A | |||
| Module indicator | ||||
| IO-LINK RUN | Green: The communication is down | |||
| Blinking green: The communication is normal | ||||
| Red: Communication is interrupted | ||||
| PWR | Green: The power supply to the module is normal | |||
| Off: The power supply of the module is not connected | ||||
| I/O | Green: The channel signal is normal | |||
| Red: The port is faulty | ||||
| AUX | Green: The auxiliary power supply is normal | |||
| Red: Auxiliary power supply is reversed | ||||
| Off: The auxiliary power supply is not connected | ||||
| Pin definition of the I/O port | ||||
| port | ![]() | ![]() | ||
| M12 | ||||
| A-code | ||||
| Female Connector | ||||
| Address Distribution | ![]() | |||
| Data port pin definition | ||||
| IO-LINK | ![]() | |||
| Port | ||||
| Stitch definition | ||||
| Underlying parameter | ||||
![]() | Shell material | PA6+GF | ||
| Shell color | Black | |||
| level of protection | IP67, epoxy full potting | |||
| Boundary dimension | 155mm×53mm×28.7mm | |||
| Weight | 227g | |||
| Operating temperature | -25℃…70℃ | |||
| Storage/transport temperature | -40℃…85℃ | |||
| Operation humidity | 5%…95% | |||
| Storage/transport humidity | 5%…95% | |||
| Operating atmosphere | 80KPa…106KPa | |||
| Preserve/transport atmospheric pressure | 80KPa…106KPa | |||
| I/O port tightening torque | M12:0.5Nm | |||
| Application environment | Conforms to EN-61131 | |||
| Vibration measurement | Comply with IEC60068-2 | |||
| Impact test | Comply with IEC60068-27 | |||
| Free drop test | Comply with IEC60068-32 | |||
| Electromagnetic Compatibility (EMC) | Comply with IEC61000-4-2,-3,-4 | |||
| Authentication | CE,RoHS | |||
| Mounting hole specification | ∅4.3mmx4 | |||
| Auxiliary power port pin definition | ||||
| Auxiliary power port | Power connection mode | M12, 5-core, L-code, Male/female | ![]() | |
| System power supply voltage us | 18…30 VDC(type.24VDC) | |||
| M12 | Auxiliary power supply voltage ua | 18…30 VDC(type.24VDC) | ||
| L-code | Total current Is | 12A | ||
| Male end | Total current la | 12A | ||
| Static working current Ic | ≤150mA | |||
| Stitch definition | Power reverse protection | have | ||
| Power port tightening torque | M12:0.5Nm | |||
|