| Sign In | Join Free | My insurersguide.com | 
 | 
| Categories | IO LINK | 
|---|---|
| Brand Name: | SUPERISYS | 
| Model Number: | IACM-DI16P | 
| Certification: | ISO\FCC\ROSH | 
| Place of Origin: | CHINA | 
| MOQ: | one | 
| Price: | Large quantity price negotiable | 
| Payment Terms: | T/T, Western Union | 
| Supply Ability: | 1000 per day | 
| Delivery Time: | 1-2 work days | 
| Shell material: | aluminium alloy | 
| Boundary dimension: | 86mm×119.6mm×31.9mm | 
| Weight: | 301g | 
| Authentication: | CE,RoHS | 
| Mounting hole specification: | Rail mounting | 
| /o Connection mode: | Terminal connection, 8x2 spring terminal, max.1.5mm² | 
| Communication protocol | Model | |||||||
|  | IACM-DI16P-ECT | IACM-DI16N-ECT | IACM-DO16P-ECT | IACM-DO16N-ECT | IACM-DIO16P-ECT | IACM-DIO16N-ECT | IACM-DI8PDO8P-ECT | IACM-DI8NDO8N-ECT | 
|  | IACM-DI16P-PN | IACM-DI16N-PN | IACM-DO16P-PN | IACM-DO16N-PN | IACM-DIO16P-PN | IACM-DIO16N-PN | IACM-DI8PDO8P-PN | IACM-DI8NDO8N-PN | 
|  | IACM-DI16P-EIP | IACM-DI16N-EIP | IACM-DO16P-EIP | IACM-DO16N-EIP | IACM-DIO16P-EIP | IACM-DIO16N-EIP | IACM-DI8PDO8P-EIP | IACM-DI8NDO8N-EIP | 
| Underlying parameter | ||||||||
| Shell material | Aluminium alloy | |||||||
| Shell color | Anodized black | |||||||
| Ievel of protection | IP20 | |||||||
| Boundary dimension | 86mm×119.6mm×31.9mm | |||||||
| Weight | 301g | |||||||
| Operating temperature | -25℃…70℃ | |||||||
| Storage/transport temperature | -40℃…85℃ | |||||||
| Operation humidity | 5%…95% | |||||||
| Storage/transport humidity | 5%…95% | |||||||
| Operating atmosphere | 80KPa…106KPa | |||||||
| Preserve/transport atmospheric pressure | 80KPa…106KPa | |||||||
| Application environment | Accord withEN-61131 | |||||||
| Vibration measurement | Accord withIEC60068-2 | |||||||
| Shock test | Accord withIEC60068-27 | |||||||
| Electromagnetic Compatibility (EMC) | Accord withIEC61000-4-2,-3,-4 | |||||||
| Authentication | CE,RoHS | |||||||
| Mounting hole specification | Rail mounting | |||||||
| Product description | 16-Channel input | 16 Channel output | 16-Channel input | 8-Channel input | ||||
| IP20 | IP20 | I/O adaptive | 8-Channel output | |||||
| Independent module | Independent module | IP20 | IP20 | |||||
| Independent module | Independent module | |||||||
| /o Connection mode | Terminal connection, 8x2 spring terminal, max.1.5mm² | |||||||
| Digital input and output parameters | ||||||||
| Number of channels | 16 | 16 | 16 | 16 | ||||
| Connection type | 8x2 spring terminal, max.1.5mm² | 8x2 spring terminal, max.1.5mm² | 8x2 spring terminal, max.1.5mm² | 8x2 spring terminal, max.1.5mm² | ||||
| input type | PNP | NPN | PNP | NPN | PNP | NPN | PNP | NPN | 
| Input diagnostic type | Supply short circuit diagnosis | Point diagnosis | Supply short circuit diagnosis | Supply short circuit diagnosis | ||||
| Switching threshold | EN 61131-2 Type 1/3 | 0V(potential group 24VDC) | EN 61131-2 Type 1/3 | EN 61131-2 Type 1/3 | ||||
| Switching frequency | 250 Hz | Resistance, sensibility, lamp | 250 Hz | 250 Hz | ||||
| Output type | PNP | NPN | PNP | NPN | ||||
| Output diagnostic type | Point diagnosis | Point diagnosis | ||||||
| Output voltage | OV(Potential group 24VDC) | OV(Potential group 24VDC) | ||||||
| Channel output current | 0.5A/ch | 0.5A/ch | ||||||
| Iloadtype | Resistance, sensibility, lamp | Resistance, sensibility, lamp | ||||||
| Module indicator | ||||||||
| EtherCat protocol | ProfiNet protocol | EtherNet/IP protocol | ||||||
| PWR | Green; The module power supply is normal. | |||||||
| Red: The power supply of the module is reversed | ||||||||
| I/o | Green: The channel signal is normal | |||||||
| Red: The port power supply is short-circuited | ||||||||
| LINK | Green: The link is normal | |||||||
| Yellow flash: The link is normal and the data communication is normal | ||||||||
| Off: The link is not established | ||||||||
| RUN | Green: indicates the OP status | SF | Red: The module is faulty | MS | Green: The module is normal | |||
| Green slow blinking; SAFEOP status | Blinking green: The module is not configured | |||||||
| Green fast blinking: The Pre-OP status is displayed | BF | Red: Internal error | Red: The module is faulty | |||||
| Off: indicates the Init state | Red blinking: Device name / | NS | Green: The network is normal | |||||
| ERR | Red blinking: A communication error occurs | IP/ | Blinking green: The communication is not established | |||||
| Off: The module is working properly | The module group status is incorrect | Red blinking: The communication is interrupted | ||||||
| Pin definition of the I/O port | ||||||||
| Schematic diagram of power terminal wiring |  |  |  |  | ||||
| IO terminal wiring diagram |  |  |  |  |  | |||
|   | 
 IP20 Rated 32 DIO Bus Modules with RoHS Compliant Authentication
                                                                                    
                        
                        
                        
                                                            IP20 Rated 32 DIO Bus Modules with RoHS Compliant Authentication
                                                    
                        
                     IACM-DI16P-IOL-20 Economical IOLINK Protocol module 16 Channel Digital Input / Output Series
                                                                                    
                        
                        
                        
                                                            IACM-DI16P-IOL-20 Economical IOLINK Protocol module 16 Channel Digital Input / Output Series
                                                    
                        
                     IACM-DO16P-IOL-V Digital Point To Point Networking Standard IOLINK Slave Station
                                                                                    
                        
                        
                        
                                                            IACM-DO16P-IOL-V Digital Point To Point Networking Standard IOLINK Slave Station
                                                    
                        
                     IACM-DI8P-IOL-M8 M8 Series IO LINK Digital Input / Output Distributed AIO Module
                                                                                    
                        
                        
                        
                                                            IACM-DI8P-IOL-M8 M8 Series IO LINK Digital Input / Output Distributed AIO Module
                                                    
                        
                     IACM-AIO8VI-IOL IP67 IO LINK Slave Module 8 Analog Input / Output Series IOLINK Protocol
                                                                                    
                        
                        
                        
                                                            IACM-AIO8VI-IOL IP67 IO LINK Slave Module 8 Analog Input / Output Series IOLINK Protocol
                                                    
                        
                     IACM-DI16P-IOL 16 Channels IO LINK Devices Distributed DIO Module With M8 Standard Interface
                                                                                    
                        
                        
                        
                                                            IACM-DI16P-IOL 16 Channels IO LINK Devices Distributed DIO Module With M8 Standard Interface
                                                    
                        
                     IACM-IOLM4A-ECT 4 Port IO LINK Master Module Industrial Ethernet Ip Protocol
                                                                                    
                        
                        
                        
                                                            IACM-IOLM4A-ECT 4 Port IO LINK Master Module Industrial Ethernet Ip Protocol
                                                    
                        
                     IACM-IOLM8A-ECT/PN Multiple IO LINK Communication 8 Port Series EtherCat Protocol
                                                                                    
                        
                        
                        
                                                            IACM-IOLM8A-ECT/PN Multiple IO LINK Communication 8 Port Series EtherCat Protocol