Sign In | Join Free | My insurersguide.com
insurersguide.com
Products
Search by Category
Home > Active Components >

IFM SV vortex flowmeters with display for water based media SV4200 SVR12XXXIRKG

Categories IFM Pressure Sensor
Brand Name: IFM
Model Number: SV4200
Certification: 3C
Place of Origin: GERMANY
MOQ: 1
Price: $383/piece
Payment Terms: T/T
Supply Ability: 1piece in stock
Delivery Time: 3 day
Packaging Details: 120*80*50mm
Weight[g]: 474
Dimensions[mm]: 110 x 45 x 72
System: gold-plated contacts
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

IFM SV vortex flowmeters with display for water based media SV4200 SVR12XXXIRKG

Product characteristics
Number of inputs and outputsNumber of digital outputs: 2
Measuring range1...20 l/min0.06...1.2 m³/h
Process connectionthreaded connection G 1/2 DN8
Application
Special featureGold-plated contacts
Applicationfor industrial applications
Mediawater; glycol solutions; coolants
Medium temperature [°C]-10...90
Pressure rating [bar]12
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SV4200-00 — 02.02.2023 —
SV4200
Vortex flow meter with display
SVR12XXXIRKG/US-100
Pressure rating [Mpa]1.2
Note on pressure ratingup to 40 °C
MAWP (for applications [bar]3.9
according to CRN)
Electrical data
Operating voltage[V]18...30 DC
Current consumption[mA]< 30
Min. insulation resistance[MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s]< 3
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2
Outputs
Total number of outputs2
Output signalswitching signal; frequency signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching
output DC
[V]2.5
Permanent current rating of
switching output DC
[mA]100
Short-circuit protectionyes
Overload protectionyes
Measuring/setting range
Measuring range1...20 l/min0.06...1.2 m³/h
Display range0...24 l/min0...1.44 m³/h
Resolution0.1 l/min0.005 m³/h
Set point SP1.2...20 l/min0.07...1.2 m³/h
Reset point rP1...19.8 l/min0.06...1.19 m³/h
Frequency endpoint, FEP4...20 l/min0.24...1.2 m³/h
Insteps of0.1 l/min0.005 m³/h
Frequency at the endpoint [Hz]100...1000
FRP
Measuring dynamics1:20
Temperature monitoring
Measuring range[°C]-10...90
Display range[°C]-30...110
Resolution[°C]0.5
Set point SP[°C]-9...90
Reset point rP[°C]-10...89
Insteps of[°C]0.5
Frequency start point, FSP[°C]-10...70
Frequency endpoint, FEP[°C]10...90
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SV4200-00 — 02.02.2023 —
SV4200
Vortex flow meter with display
SVR12XXXIRKG/US-100
Frequency at the endpoint [Hz]100...1000
FRP
Accuracy / deviations
Flow monitoring
Accuracy (in the measuring
range)
± 2 % MEW; (water)
Repeatability± 0,5 % MEW
Temperature monitoring
Accuracy [K]± 1
Response times
Flow monitoring
Response time[s]1; (dAP = 0)
Damping process value dAP[s]0...5
Temperature monitoring
Dynamic response T05 / T09 [s]T09 = 6
Software / programming
Parameter setting optionshysteresis / window; normally open / normally closed; switching logic;
frequency output; switch-on/switch-off delay; Damping; Display unit
Interfaces
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
ProfilesSmart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO modeyes
Required master port typeA
Process data analogue2
Process data binary2
Min. process cycle time [ms]3
Supported DeviceIDsType of operationDeviceID
Default484
Operating conditions
Ambient temperature[°C]0...60
Note on ambient temperaturemedium temperature < 80 °C
medium temperature < 90 °C: 0...50 °C
Storage temperature[°C]-20...80
ProtectionIP 65; IP 67
Tests / approvals
EMCDIN EN 61000-6-2
DIN EN 61000-6-3
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SV4200-00 — 02.02.2023 —
SV4200
Vortex flow meter with display
SVR12XXXIRKG/US-100
CPA approvalmodel number001VO
accuracy class-
maximum allowable error± 2 % FS
Q (min)0,09 m³/h
Q (t)0,24 m³/h
Q (max)1,2 m³/h
Shock resistanceDIN EN 60068-2-275 g (11 ms)
Vibration resistanceDIN EN 60068-2-6with water / 10...50 Hz 1 mm
with water / 50...2000 Hz 2 g
MTTF [years]342
UL approvalUL Approval no.I001
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight[g]474
Materialsstainless steel (1.4404 / 316L); PC; PBT+PC-GF30; PPS; TPE-U
Materials (wetted parts)stainless steel (1.4404 / 316L); ETFE; PA 6T; PPS; FKM
Tightening torque[Nm]30
Process connectionthreaded connection G 1/2 DN8
Remarks
RemarksMW = measured value
MEW = Final value of the measuring range
Pack quantity1 pcs.
Electrical connection
Connector: 1 x M12; coding: A; Contacts: gold-plated
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SV4200-00 — 02.02.2023 —
SV4200
Vortex flow meter with display
SVR12XXXIRKG/US-100
Connection
OUT1: Flow monitoring
- switching output
- frequency output
- IO-Link
OUT2: flow monitoring and temperature monitoring
- switching output
- frequency output
colours to DIN EN 60947-5-2
Core colours :
BK = black
BN = brown
BU = blue
WH = white
Diagrams and graphs
Pressure lossdP Pressure loss
Q volumetric flow quantity
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SV4200-00 — 02.02.2023 —
SV4200
Vortex flow meter with display
SVR12XXXIRKG/US-100
pressure rating (bar)
Quality IFM SV vortex flowmeters with display for water based media SV4200 SVR12XXXIRKG wholesale