                                                                                     Brand Name:QIUPU Model Number:FLN36-12/630 Place of Origin:WENZHOU High Voltage SF6 Load Breaker Switch Insulation and Operation Mechanism with Switchgear Sulphur hexafluoride (SF6) is a good gas insulator. Its typical application is gas insulation in high-voltage switchgear of power supply systems. When the sulphur ...  | 
                    
                                                    WENZHOU QIUPU ELECTRIC POWER CO., LTD.
                                                
                                                    
                        
                        
                         Zhejiang  | 
                
| 
                                                    
                                 | 
                    
                        
                                                                                     Brand Name:Tianan Electric Model Number:FT16-40.5 Place of Origin:CHINA ...Load Breaker Switch ,Load Switch - Fuse Combinations General FT16-40.5,FT16-40.5R is applied in power grid with AC 50HZ,rated voltage of 35Kv.It can be applied in breaking the load current,overload current and short-circuit current.The product is the main element of HXGT16-40.5 indoor AC metal-clad switchgear...  | 
                    
                                                    Ningbo Tianan (Group) Co.,Ltd.
                                                
                                                    
                        
                        
                         Zhejiang  | 
                
| 
                                                    
                                 | 
                    
                        
                                                                                     Place of Origin:Zhejiang, China Brand Name:Kampa Model Number:FZN25-12 ... power equipment for load control and short circuit protection purposes, load switch division and load, closed Loop current, no load transformer cable charging current. Switchgear can be up to the rated short-circuit breaking current of any current.  | 
                    
                                                    Yueqing Kampa Electric Co., Ltd.
                                                
                                                    
                        
                        
                         
  | 
                
| 
                                                    
                                 | 
                    
                        
                                                                                     Place of Origin:china Brand Name:XK Model Number:FN12 ...load break switch electric isolator switch vacuum load break switch Hot sale 12KV safety indoor AC high voltage load breaker switch Product Description A load break switch ie. on load break switch (LBS) which is a capable small fault current breaking switchgear. It is not like VCB or GCB which can even breaking short circuit current, Thus load break switch is actual a on load switching on/off switchgear...  | 
                    
                                                    ZHEJIANG XINKOU POWER EQUIPMENT CO.,LTD
                                                
                                                    
                        
                        
                         Zhejiang  | 
                
| 
                                                    
                                 | 
                    
                        
                                                                                     Brand Name:XG Model Number:FLN36 Place of Origin:XIAN ... extinguishing room with opening, closing, and grounding, and high fracture insulation. It is a new generation of high-voltage load switch widely used. City grid 2.Application FLRN- 36 series SF6 load switch. It is small in size and light in weight, and is  | 
                    
                                                    Xi'an Xigao Electricenergy Group Co., Ltd.
                                                
                                                    
                        
                        
                         Shanxi  | 
                
| 
                                                    
                                 | 
                    
                        
                                                                                     Brand Name:KNKONG Model Number:SF6 Place of Origin:China ... medium. There are three positions for closing, opening and grounding inside the switch. It has small size, easy installation and use, and strong environmental adaptability. Physical properties SF6 is a relatively heavy gas. Under the same conditions, its  | 
                    
                                                    Knkong Electric Co.,Ltd
                                                
                                                    
                        
                        
                         Henan  | 
                
| 
                                                    
                                 | 
                    
                        
                                                                                     Brand Name:RISING Model Number:RSYZ-IV Place of Origin:China ... more and more attention has been paid to the detection of on-load tap switch. In the electrical equipment handover and preventive test regulations, it is required to check the action sequence of on-load tap changer, measure switching time, etc.The  | 
                    
                                                    Wuhan Rising Electric Co., Ltd.
                                                
                                                    
                        
                        
                         Hubei  | 
                
| 
                                                    
                                 | 
                    
                        
                                                                                     Brand Name:ERFA Model Number:ZN85-40.5 Place of Origin:CHINA,XIAN ...Breaker General Description ZN85-40.5/T type indoor high voltage indoor vacuum circuit-breaker is used for switchgear KYN6140.5(Z),it is most new type of power supply and distribution equipment.This product is accordance with GB1984-2003 stand.This series include:Vacuum circuit breaker truck,isolation truck and fuse truck. Structural characteristics: 1. This vacuum circuit breaker...  | 
                    
                                                    ERFA Industries Group
                                                
                                                    
                        
                        
                         
  | 
                
| 
                                                    
                                 | 
                    
                        
                                                                                     Brand Name:TYHD Model Number:TYHD-ZW32 Place of Origin:China, Beijing ...breaker is combined of ZW32 vacuum circuit breaker and CH4 Recloser control . Standard IEC56-427 HV.AC circuit breaker GB1984-2003 HV.AC circuit breaker GB/T11022-1999 Common technology of HV.AC switchgear and Recloser Control equipments DL/T403-2000 Order technology conditions of 12-40.5kV HV.AC circuit breaker Q/TG35-JT Technology conditions of ZW32-15KV HV-AC outdoor vacuum circuit breaker...  | 
                    
                                                    Beijing Tianyihongda Science & Technology Development Co., LTD
                                                
                                                    
                        
                        
                         Beijing  | 
                
| 
                                                    
                                 | 
                    
                        
                                                                                     Brand Name:UBARO Model Number:ZG-TD-1CH Place of Origin:China ...load of 250W, this breaker switch can handle even the most demanding electrical needs. And with a standby power of only 0.5W, it won't waste energy when not in use. The ZigBee Standard of IEEE 802.15.4 ensures reliable and secure communication with other ZigBee devices. Whether you are a professional electrician or a DIY enthusiast, our breaker switch...  | 
                    
                                                    Shenzhen Ubero Technology Ltd.
                                                
                                                    
                        
                        
                         Guangdong  | 
                
| 
                                                    
                                 | 
                    
                        
                                                                                     Brand Name:Suntech Model Number:FLN36-12 Place of Origin:Ningbo,China ...Load Break Switch FLN type indoor high voltage AC load breaker switch refer to international new technology and develop the switching equipment in according to the relevant standards in China's electric power system. Its performance indicators in full compliance IEC420, 694,129 and national standards GB3804-2004“3.6kV-0.5kV high voltage AC load breaker switch" GB1985-2004“high-voltage AC isolation switch  | 
                    
                                                    Ningbo Suntech Power Machinery Tools Co.,Ltd.
                                                
                                                    
                        
                        
                         Zhejiang  | 
                
| 
                                                    
                                 | 
                    
                        
                                                                                     Brand Name:Baikong Model Number:ZHV-12D Place of Origin:Sichuan,China ... mm 2-3 3 Open distance mm 8-10 4 bounce ms ≤2 5 Mean speed of gate separation m/s 0.6-1.4 6 Closing average speed m/s 0.4-1.1 7 Three phases of switching off ms ≤2 8 Closing Ihree phases ms ≤2 New type gas-filled cabinet circuit breaker switch,  | 
                    
                                                    Sichuan Baikong Electric Technology Co., Ltd.
                                                
                                                    
                        
                        
                         Sichuan  | 
                
| 
                                                    
                                 | 
                    
                        
                                                                                     Brand Name:Rich Model Number:UPK Series Place of Origin:China IP65 Waterproof Three-phase Rotary Isolation Disconnect Switch Rotary Cam Switch With Box The UKP Load Break Switch is an essential component for ensuring safe and efficient load switching and isolation in medium-voltage systems. For more information or ...  | 
                    
                                                    Yueqing Richuang Automation Equipment Co.,Ltd
                                                
                                                    
                        
                        
                         Zhejiang  | 
                
| 
                                                    
                                 | 
                    
                        
                                                                                     Brand Name:NBSe/OEM Model Number:N30 Place of Origin:CHINA 1P+N MCB,N30-32 MCB Stock Manufacturer,Switchgear Circuit Breaker 1. Application N30-32 is used in the single phase circuit of AC 50Hz/60Hz, rated voltage 230V or below for protecting circuit from ...  | 
                    
                                                    Wenzhou New Blue Sky Electrical Co.,Ltd
                                                
                                                    
                        
                        
                         Zhejiang  | 
                
| 
                                                    
                                 | 
                    
                        
                                                                                     Brand Name:HENGFENGYOU Model Number:GGD. GCS Place of Origin:China China GCK GCS Series Draw-Out Type Low Voltage Switchgear Electric Distribution Switch Cabinet Switchgear GCS low voltage withdrawable type switch cabinet is suitable for a power distribution system of AC 50Hz or 60HZ, rated voltage 660V and below, rated ...  | 
                    
                                                    Qingdao Hengfengyou Electrical Engineering Co., Ltd.
                                                
                                                    
                        
                        
                         Shandong  | 
                
| 
                                                    
                                 | 
                    
                        
                                                                                     Brand Name:XIWUER Model Number:Embedded Pole Smart Type High Voltage Vacuum Circuit Breaker Place of Origin:XIAN, SHANNXI CHINA ...load break switch Introduction Three-phase, electronically controlled, vacuum- interrupting distribution automation switch provides reliable, economical switching, sectionalizing, advanced metering, and automation systems for distribution circuits rated up to 38 kV.The switch...  | 
                    
                                                    XIAN XIWUER ELECTRONIC AND INFO. CO., LTD
                                                
                                                    
                        
                        
                         Shaanxi  | 
                
| 
                                                    
                                 | 
                    
                        
                                                                                     Place of Origin:China Brand Name:Comking Model Number:CKFY(R) 1. Description CKWZ is a three-phase AC outdoor vacuum circuit breaker maximum up to 24kV rated voltage and 50Hz rated frequency. 2. Working Condition 2.1 Ambient air temperature: -45℃~+40℃,daily range of temperature: diurnal variation 25℃ 2.2 Relative ...  | 
                    
                                                    Zhuhai Comking Electric Co.,Ltd.
                                                
                                                    
                        
                        
                         Guangdong  | 
                
| 
                                                    
                                 | 
                    
                        
                                                                                     Brand Name:Milky Way Model Number:Bitumen Galvanized Electrical Power Pole With Circuit Breaker Switch Place of Origin:China ...0.25m from the top. Under these loads, the safety factor with respect to the elastic limit of the steel is larger than 1.8. The post also resists a torque equal to (F+V) ×1m. Tests shows the load intervened when breaking is around 2 times of design load.  | 
                    
                                                    Jiangsu milky way steel poles co.,ltd
                                                
                                                    
                        
                        
                         Jiangsu  |