FKN12-12RD Indoor Vacuum High Voltage Load Breaker Switch 3 Phase 12kV 1250A
|
...High Voltage Indoor Vacuum Load switch with switcgear The type FKN12-12RD high voltage indoor vacuum load switch and electrical comination is use for Three phase alternating current Concurrent 50HZ industrial power euipments , its can laod control and protect short current . Load switch is open-close load......
WENZHOU QIUPU ELECTRIC POWER CO., LTD.
|
12KA Indoor High Voltage Load Disconnect Switch Multi Size Can Be Available
|
... of China" on the coast of the East China Sea. It has the most beautiful wind and convenient transportation. Zhejiang Xinkou Power Equipment Co., Ltd. is a high-tech enterprise integrating the development, design, manufacture, sales and import of high and...
ZHEJIANG XINKOU POWER EQUIPMENT CO.,LTD
|
50Hz High Voltage Load Break Switch Manual 630A MCCB Circuit Breaker
|
... mm 2-3 3 Open distance mm 8-10 4 bounce ms ≤2 5 Mean speed of gate separation m/s 0.6-1.4 6 Closing average speed m/s 0.4-1.1 7 Three phases of switching off ms ≤2 8 Closing Ihree phases ms ≤2 New type gas-filled cabinet circuit breaker switch,...
Sichuan Baikong Electric Technology Co., Ltd.
|
40.5KV High Voltage Load Break Switch
|
Indoor High Voltage Vacuum Load Breaker Switch ,Load Switch - Fuse Combinations General FT16-40.5,FT16-40.5R is applied in power grid with AC 50HZ,rated voltage of 35Kv.It can be applied in breaking the load current,overload current and short-circuit ......
Ningbo Tianan (Group) Co.,Ltd.
|
24kv 630a High Voltage Load Break Switch Light Weight
|
... the 10kV, 24kV, and 35kV power systems on load situations. Compared to product of the kind in a foreign country, its technical parameter has reached the international level with the features of small volume and lightweight. 2. ......
Xi'an Xigao Electricenergy Group Co., Ltd.
|
Indoor High Voltage Load Break Switch FN12-12 12KV 630A
|
Indoor High Voltage Load Break Switch FN12-12 12KV 630A Service Condition A. The ambient air temperature: Max.: +40 °C. Min: -25 °C. B. The altitude ≤ 1000m. C. The relatire humidity of air. daily average ≤ 95%. monthly average ≤ 90%. D. The ambient air......
Yueqing Kampa Electric Co., Ltd.
|
Load Control Air Load Break Switch , High Voltage Load Break Switch Short Circuit Protection
|
1. Description CKWZ is a three-phase AC outdoor vacuum circuit breaker maximum up to 24kV rated voltage and 50Hz rated frequency. 2. Working Condition 2.1 Ambient air temperature: -45℃~+40℃,daily range of temperature: diurnal variation 25℃ 2.2 Relative ......
Zhuhai Comking Electric Co.,Ltd.
|
Customized 10kV High Voltage Load Break Switch For Ring Main Unit
|
...
Shenzhen Dong Sheng Yuan Electrical Equipment Co., Ltd.
|
Cba-III IEC62271 High Voltage Circuit Breaker Timing Test Set
|
...High Voltage Circuit Breaker Timing Test Set Introduction: CBA-III IEC62271 High Voltage Circuit Breaker Timing Test Set is used for testing, analyzing and assessing power system circuit breakers, mechanical characteristics of load switches and isolated switches and other AC high voltage switches, contact resistance, Arcing contacts and vibration characteristics etc. CBA-III IEC62271 High Voltage Circuit Breaker......
Delta Technology (Chongqing) Co., Ltd.
|
Digital High Voltage Circuit Breaker Analyzer Hv Switch Dynamic Characteric Tester
|
...High voltage circuit breaker analyzer Product Description The mechanical characteristic parameter is one of the important parameters to judge the performance of the circuit breaker. XHJJ302A high-voltage circuit breaker analyzer (high-voltage switch mechanical characteristic tester) is based on the latest "High-voltage AC Circuit Breaker......
Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
|