All fast measuring dissolved oxygen detection device wholesalers & fast measuring dissolved oxygen detection device manufacturers come from members. We doesn't provide fast measuring dissolved oxygen detection device products or service, please contact them directly and verify their companies info carefully.
| Total 67 products from fast measuring dissolved oxygen detection device Manufactures & Suppliers |
|
|
|
Brand Name:KACISE Model Number:KWS-670A Place of Origin:china ... method, it can achieve 90% of the measurement accuracy within 120s. This device offers both timed measurement and real - time detection modes. Users can choose the most suitable mode according to their needs. With its high - speed measurement, it is |
Xi'an Kacise Optronics Co.,Ltd.
Shaanxi |
|
|
Brand Name:Desun Uniwill Model Number:DS-380 Place of Origin:China ... instrument for continuous monitoring and control of dissolved oxygen, providing real-time measurement results for various industrial processes. Online dissolved oxygen sensor is very suitable for online monitoring and control of dissolved oxygen in |
Xi'an Desun Uniwill Electronic Technology Co., Ltd.
Shaanxi |
|
|
Brand Name:Daruifuno Model Number:OPD700 Place of Origin:China ...water. Using the principle of electrochemical sensing, the electrochemical reaction of oxygen on the surface of the electrode is used to measure the content of dissolved oxygen. The detection of dissolved oxygen sensors in aquaculture is very necessary for |
Suzhou Delfino Environmental Technology Co., Ltd.
Jiangsu |
|
|
Brand Name:JUGE Model Number:AG-DO700Y Place of Origin:Nanjing, China ...Dissolved Oxygen Analyzer Clark electrode >>Principle Based on Clark electrode technology, specifically designed for measuring trace-level (ppb level) oxygen concentrations in water. >>Application ○ Detection and analysis of low-concentration dissolved oxygen in power plants, waste heat boilers, deoxygenated water, etc. ○ Trace oxygen detection in semiconductor ultrapure water. >>Feature High-Precision Sensor: Detection |
Nanjing Juge Environmental Technology Co., Ltd.
Jiangsu |
|
|
Brand Name:KaiNaFu Model Number:KNF-103A Place of Origin:Shenzhen ... adopts the advanced fluorescence quenching principle to measure the dissolved oxygen concentration in water without loss. It features no pollution, long service life, good stability and low maintenance difficulty. The unique optical detection method of |
Shenzhen Kainafu Technology Co., Ltd.
|
|
|
Brand Name:YIERYI Model Number:JBP-70A Place of Origin:China Measuring range: 1. Dissolved oxygen: (0.0~20.0)mg/L 2. Temperature: (0 ~ 40) °C Basic error: 1. Dissolved oxygen: ±0.3mg/L 2. Temperature: ±1°C LCD Automatic temperature compensation, fast response time Portable, easy to carry With our factory dissolved oxygen... |
SHEN ZHEN YIERYI Technology Co., Ltd
|
|
|
Brand Name:NANBEI Model Number:JPSL-606L DO Analyzer Place of Origin:China ...Dissolved Oxygen Analyzer , Dissolved Oxygen Controller Brief introduction of DO meter Dissolved oxygen analyzer is the determination of dissolved oxygen in water device, the working principle is oxygen through the diaphragm by the working electrode reduction, resulting in oxygen concentration is proportional to the diffusion current, by measuring this current, the concentration of dissolved oxygen in water. It can be used to measure |
NANBEI INSTRUMENT LIMITED
Henan |
|
|
Brand Name:Yokogawa Model Number:DO30G-NN-50-10-PN Place of Origin:Japan ... water treatment. It is also effective in river monitoring, intake protection, fish farming and other fields where water quality is important. This galvanic cell has a fast response time and |
Mengchuan Instrument Co,Ltd.
Zhejiang |
|
|
Brand Name:Readycome Place of Origin:China Vertical Dissolved Oxygen PH Analyzer Water Quality Monitoring Station Voltage 220V Water quality monitoring Dissolved oxygen Ammonia nitrogen PH Conductivity ORP Gauge height Water temperature Tturbidity Internet traffic Environmental monitoring Air ... |
Sichuan Readycome Trading Co., Ltd.
Sichuan |
|
|
Brand Name:E+H Model Number:COS61-A2F0 Place of Origin:Germany Dissolved oxygen sensor Oxymax COS61-A2F0 Optical oxygen sensor Description: Manufacturer : Endress+Hauser Product No. :COS61-A2F0 Measuring range: 0,0-20 mg/l Compatibility, Sensor: COS31, (digital) 2 Cable Length: 15 m Shipping weight:3kg Additional Informaiton: Oxymax COS61 is a high-performance oxygen sensor that offers fast, accurate and drift-free measurement... |
GREAT SYSTEM INDUSTRY CO. LTD
|
|
|
Brand Name:ZONEWU Model Number:LW101D-DO Place of Origin:Xiamen ...Features: LoRa water quality dissolved oxygen sensor is a device used to measure the concentration of dissolved oxygen in a solution. It adopts the principle of fluorescence measurement and does not require oxygen consumption or electrolyte. The sensor is ... |
Xiamen ZoneWu Technology Co., LTD.
Fujian |
|
|
Brand Name:E+H Model Number:COS61-A2F0 Place of Origin:Germany Dissolved oxygen sensor Oxymax COS61-A2F0 Optical oxygen sensor Description: Manufacturer : Endress+Hauser Product No. :COS61-A2F0 Measuring range: 0,0-20 mg/l Compatibility, Sensor: COS31, (digital) 2 Cable Length: 15 m Shipping weight:3kg Additional Informaiton: Oxymax COS61 is a high-performance oxygen sensor that offers fast, accurate and drift-free measurement... |
GREAT SYSTEM INDUSTRY CO. LTD
|
|
|
Brand Name:Alphasense Model Number:LFO2-A1 Place of Origin:Britain ...Oxygen Sensor Is Used Oxygen Alarm Devices Features: Measurement range: The oxygen concentration detection range is from 0% to 30%, suitable for oxygen monitoring in regular environments. Working life: The typical working life exceeds 5 years, featuring a long service life and reducing the frequency of replacements. Output signal: At an oxygen... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Categories:Water Quality Meter Country/Region:china ...dissolved oxygen meter, the fluorescence probe is efficient and stable, no frequent correction, no need to replace the film jacket/electrolyte, interference resistance, low maintenance costs, suitable for freshwater aquaculture, environmental detection and other fields. Product Parameters DO measuring... |
Shenzhen Bestone Industrial Co.Ltd.
|
|
|
Brand Name:Pray-med Model Number:PSR 11-55-HL Place of Origin:USA O2 Sensor PSR 11-55-HL/PSR-11-55-HL Oxygen Sensor For Lowenstein Product Specifications Measuring range 0-100%O2 Signal Output (1) 10-13.5 mV Response Time 90% 6 Seconds Accuracy FullScale (2) ±1% Accuracy FS Over Operating Temperature (3) ±5% Drift(%... |
Shenzhen Pray-med Technology Co.,Ltd
Guangdong |
|
|
Brand Name:Lixian Model Number:HZ-1342 Place of Origin:China Automotive Testing Equipment Wheel Run-out Measuring Machine Detection Line Type Automotive Testing Equipment Summary The device is a car wheel roundness detection line, with precision height, fast beat, functional and other multiple advantages. The center... |
Dongguan Lixian Instrument Scientific Co.,LTD
Guangdong |
|
|
Brand Name:Safegas Model Number:SKY2000-O2-WH Place of Origin:China ...make sure O2 reading accurancy, more reliable, more convenient, more easier. Meanwhile, 30%VOL O2 Oxygen gas detector is a kind of fast response and high accuracy gas measurement device. And the 30%VOL O2 Oxygen gas detector is with inner sampling pump, |
Shenzhen YuanTe Technology Co., Ltd. (Safegas)
Guangdong |
|
|
Brand Name:Wayeal Model Number:SFJ-231D Place of Origin:Anhui, China ... detection device that utilizes a Helium mass spectrometer to detect and measure leaks in industrial vacuum systems. This Helium Leak Detector is designed to quickly and accurately detect and measure leaks, including very small leaks, and is suitable for a |
Anhui Wanyi Science and Technology Co., Ltd.
Anhui |
|
|
Brand Name:gorgeous Model Number:agf55 Place of Origin:China Multifunction skin care oxygen hydra facial therapy deep cuticle cleansing AI smart skin measurement rf jet peel device seven in one/ with skin detection analyzer/ skin tightening device Product Description Vacuumrange 700mmHg Outputcontrol Touchscreen&... |
Gorgeous Beauty Equipment Manufacture
|
|
|
Brand Name:Hundred Medical Model Number:Breathing Filter Place of Origin:China ... Range 70%-99% The Fingertip Pulse Oximeter for Rapid Detection is a convenient and portable device designed for quick and accurate monitoring of oxygen saturation (SpO2) and pulse rate. This compact device is perfect for use at home, in hospitals, or |
Sichuan Hundred Medcal Technology Co., Ltd.
|