| Sign In | Join Free | My insurersguide.com |
|
All electronic closed loop current sensor wholesalers & electronic closed loop current sensor manufacturers come from members. We doesn't provide electronic closed loop current sensor products or service, please contact them directly and verify their companies info carefully.
| Total 510 products from electronic closed loop current sensor Manufactures & Suppliers |
|
|
|
Model Number:CSNE151-100 Place of Origin:USA ... or Hall effect type. Using the zero-flux method (feedback system), it continuously controls the magnetic flux in the sensor core to zero. The current required to balance the zero flux is proportional to the primary current flowing through the |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:TOKEN Model Number:TBC-AP Place of Origin:CHINA ...Closed Loop Current Sensor For Electromagnetic Heater And Filter Use Product Description Input current 25-200A High Accuracy Closed loop hall effect current sensor for electromagnetic heater; fliter;power meter and also power system equipment use This current sensor used for the electronic current... |
Nanjing Token Electronics Science&Technology Co., Ltd.
|
|
|
Brand Name:Acrel Model Number:AHBC-LTA Place of Origin:China Current Transformer (CT) is used to transform the high AC current to small easily manageable values. They are connected with the panel meter or relay and they can help to measure the current or protect the equipment. Technical Features Technical parameter ... |
Jiangsu Acrel Electrical Manufacturing Co., LTD.
Jiangsu |
|
|
Brand Name:iqualitrol Model Number:HBE-3000AS ...-3000AS digital eyepiece electronic Brinell hardness tester adopts advanced electronic sensor loading technology through the closed-loop control system, the CPU controls the sensor to collect signals. The stepping motor automatically loads and unloads the |
Dongguan Quality Control Technology Co., Ltd.
Guangdong |
|
|
Brand Name:iqualitrol Model Number:HBE-3000AS ...Electronic Brinell Hardness Tester Closed Loop Control Sensor Loading Model: HBE-3000AS Download Technical Data: iqualitrol Brinell Hardness Tester HBE-3000AS Brief Introduction: iqualitrol HBE-3000AS digital eyepiece electronic Brinell hardness tester adopts advanced electronic sensor loading technology through the closed-loop control system, the CPU controls the sensor... |
DongGuan Q1-Test Equipment Co., Ltd.
Guangdong |
|
|
Brand Name:LEM Model Number:LF1005-SSP16 Place of Origin:Switzerland ...Loop Current Sensor ±1000A measurement range The LEM LF1005-SSP16 is a high-precision current sensor designed to measure AC and DC currents in various industrial applications. As part of the comprehensive LEM LF series, which includes models such as LF200-S, LF305-S, LF505-S, and LF1005-S, this sensor... |
Xiamen Changxuyuan Trading Co., Ltd
Fujian |
|
|
Brand Name:YOUBI Model Number:HBE-3000A Place of Origin:China Robust Digital Brinell Hardness Tester With Tungsten Carbide Ball Indenter Professional digital Brinell hardness testing equipment designed for precise material hardness measurement in industrial applications. Application Scope Determination of Brinell ... |
Dongguan Youbi Test Equipment Co.,Ltd
Guangdong |
|
|
Brand Name:Mitsubishi Model Number:HC-SFS52G1H Place of Origin:Japan Rated Output:: 0.5kW SRated Speed:: 2000 RPM Power Supply Specification: 3AC 126V Brand: Mitsubishi Industrial Servo Motor Model Item: HC-SFS52G1H Plan Of Original: Japan High Light: ewing machine servo motor , ac servo motor HC-SFS52G1 3AC 126V 3.2AMP ... |
LINTURE Technology CO.,LTD
|
|
|
Brand Name:Shinhom Model Number:HBC-LSR5 Place of Origin:China ...Closed Loop Mode Hall Effect Current Sensor with 0 to 50A input,Supply voltage 5V HBC-LSR5 series multi-range current sensor is a closed loop device based on the measuring principle of the hall effect and null balance method, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents. Directions for use When the current... |
Shaanxi Shinhom Enterprise Co.,Ltd
Shaanxi |
|
|
Brand Name:Original Factory Model Number:LESR25-NP Place of Origin:CN ...Sensor IC 25A 4.75V To 5.25V 1 Channel Hall Effect Current Sensors Product Description LESR25-NP is 25A 1 Channel Hall Effect Current Sensors. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation betweenthe primary and the secondary circuit. Specifications Part Status Active For Measuring AC/DC Sensor Type Hall Effect, Closed Loop Current... |
ShenZhen Mingjiada Electronics Co.,Ltd.
|
|
|
Place of Origin:Tianjin, China Brand Name:grewin Model Number:GWRCT Close loop hall current sensors is a new generation of current sensor which applies hall effect principle, can measure direct current, alternating current, pulse and current of various irregular wave forms in electrical isolation conditions. 1.We have abtained VDE,UL,CE,ROHS,ISO9000 ,ETL Approal and SGS Audit Supplier in China 2.The following is our detailed information of our pcb mounting closed loop sensor hall norminal current... |
Tianjin Grewin Technology Co., Ltd
Tianjin |
|
|
Brand Name:SG Model Number:Hall Effect Current Sensor Place of Origin:Dongguan China ... (direct) and closed loop (magnetic balance). The advantage of the direct-amplification Hall sensor is that the circuit form is simple and the cost is relatively low; the disadvantage is that the accuracy and linearity are poor, the response time is slow, |
Dongguan Chenglue Electronic co.,Ltd
Guangdong |
|
|
Brand Name:Allegro MicroSystems Model Number:ACS723LLCTR-20AU-T Place of Origin:Original ... integrated digital temperature compensation circuitry allows for near closed loop accuracy over temperature in an open loop sensor • UL60950-1 (ed. 2) certified □ Dielectric Strength Voltage = 2.4 kVrms □ Basic Isolation Working Voltage = 420 Vpk/ |
Shenzhen Retechip Electronics Co., Ltd
Guangdong |
|
|
Brand Name:Casun Model Number:B20SHD4351-56GPQ Place of Origin:CHINA ... and has served more than 800 customers Motor Specifications Step Angle 1.8° Frame Size 20 mm Number of Phase 2 Phase Rated Current 0.5 A Holding Torque 14 mN.m |
GUANGZHOU FUDE ELECTRONIC TECHNOLOGY CO.,LTD
Guangdong |
|
|
Brand Name:Jkongmotor Model Number:JK86HSN120 Place of Origin:Jiangsu, China (Mainland) ...Closed loop Stepper Servo Motor + Mach3 Breakout Board + Driver + Power Supply Specification item value Warranty 1 YEAR Place of Origin China Brand Name Jkongmotor Model Number Nema 34 Closed Loop stepper motor kits Phase 2 Type Hybrid Current / Phase 6A Product name Nema 34 Closed Loop Stepper Motor Step angle 1.8 degree Motor length 78mm-155mm Current... |
CHANGZHOU JKONGMOTOR CO.,LTD
Jiangsu |
|
|
Model Number:LC86H3114+LCDA2260E Brand Name:LICHUAN Place of Origin:Guangdong, China Packing List NO. Product Name Model / Description Quantity 1 Lichuan 3 phase closed loop stepper motor LC86H3114 1 2 Lichuan 3 phase closed loop digital stepper drive LCDA2260E 1 3 Encoder Cable Standard (3m) 1 Products Description 3 phase Closed-loop ... |
Shenzhen Xinlichuan Electric Co., Ltd.
|
|
|
Brand Name:HUATEC Model Number:HB-3000E Place of Origin:China ... the closed-loop control system, the CPU controls the sensor to collect signals. The stepping motor automatically loads and unloads the test force, and can automatically compensate the test force to ensure the force ... |
HUATEC GROUP CORPORATION
Beijing |
|
|
Brand Name:HEJIE Place of Origin:CHANGZHOU,CHINA ...Closed Loop Stepper Motor Rated Current 4.2A Rated Torque 2.2NM For Textile Machine 1. Electrical Specification of nema 23 closed loop stepper motor 2.2N.m: Model No. Step Angle Motor Length Current /Phase Resistance /Phase Inductance /Phase Holding Torque # of Leads Detent Torque Rotor Inertia Mass ( °) (L)mm A Ω mH N.m No. Kg.cm g.cm Kg 57BYGHB80-4204 1.8 80 4.2 0.7 2.0 2.2 4 7 500 1.4 2. Dimensions:(unit=mm) 57 close loop |
Changzhou Hejie Motor Co., Ltd
Jiangsu |
|
|
Brand Name:Gyrosens Model Number:GSGYR103F Place of Origin:china ...sensor based on the optical Sagnac effect for measuring the rotational angular velocity of the carrier along the sensitive axis. The digital closed-loop detection circuit is used to extract the optical path difference of the clockwise light caused by the external physical angular speed, and the voltage signal of the optical path signal is modulated and demodulation, and the closed loop |
Xi'an Kacise Optronics Co.,Ltd.
Shaanxi |