| Sign In | Join Free | My insurersguide.com |
|
| Categories | Stationary Meter Test Bench |
|---|---|
| Brand Name: | GENY |
| Model Number: | YC1893D |
| Certification: | ISO, CE |
| Place of Origin: | CHINA |
| MOQ: | 1pcs |
| Price: | negotiation |
| Payment Terms: | L/C,T/T,D/P |
| Supply Ability: | 30 PCS per month |
| Delivery Time: | 30 days after order confirmed |
| Packaging Details: | Plywood case |
| Storage temperature: | -5℃ to 55℃ |
| Ambient operation temperature:: | +5℃ to 50℃ |
| Relative humidity: | 45% to 95% |
| Test voltage output(Phase-Neutral): | P-N (0 to 320V) , P-P (0 to 550 V) customized |
| Test current output: | 3 × (1mA - 120A) |
| Company Info. |
| Guangzhou GENY Electric Co., Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |
Guangzhou GENY Electric Co. Ltd.offers a high-precision Three Phase Energy Meter Test Bench, designed to test and calibrate 1 to 20 single-phase or three-phase energy meters simultaneously. The system complies with IEC standards 62052-11 and 62053 , supporting accuracy classes 0.1, 0.2, 0.5, 1, and 2.
This universal energy meter test system is engineered for electric utilities, testing labs, and meter manufacturers looking for a reliable, accurate, and versatile testing platform.
Voltage | 3x230/400 V+10% -15%,50Hz ± 2% |
Frequency | 50/60Hz±2Hz |
Power capacity | > 3 ×6kVA |
Voltage | |
Test voltage output | P-N (0 to 320V) , P-P (0 to 550 V) customized |
Power of the voltage output | 3×1000VA |
Resolution | Better than 0.01% of full scale value of range |
Setting accuracy | Better than 0.02% at the final range value |
Stability | Better than 0.005%/h (integration time 150 s) |
Load regulation from 0-max. load | < 0.01% |
Distortion factor | < 0.3% for linear resistance load |
Harmonics | 2nd - 21st free programmable |
Power efficiency | 65% ~85% (Full load) |
Current | |
Test current output | 3 × (1mA - 120A) |
Power of the current output | 3×1500VA |
Resolution | Better than 0.01% of full scale value of range |
Setting accuracy | Better than 0.02% at the final range value |
Stability | Better than 0.005%/h (integration time 150 s) |
Load regulation from 0-max. load | < 0.01% |
Distortion factor | < 0.3% for linear resistance load |
Harmonics | 2nd - 21st free programmable |
Power efficiency | 65% ~85% (Full load) |
Phase angle | |
Range | 0 -- 360° |
Resolution | 0.01° |
Setting accuracy | 0.1° |
Frequency | |
Range | 45Hz ~ 65Hz (adjustable in steps of 0. 1Hz) |
Resolution | 0.01Hz |




|