| Sign In | Join Free | My insurersguide.com |
|
| Categories | Other |
|---|---|
| Brand Name: | Ametek |
| Model Number: | WDG-IV UOP |
| MOQ: | 1 |
| Price: | US $125000.00 - 137800.00/ Unit |
| Payment Terms: | T/T |
| Supply Ability: | 50 units per year |
| Delivery Time: | 90 work days |
| Packaging Details: | Carton + Wooden crate + Protective packaging |
| Sensing principle: | Zirconia (in-situ probe) |
| Typical applications: | Refinery fired heaters / reformer / cracking furnaces |
| Output range: | From 0-1% to 0-100% |
| Contact rating: | 0.5A, 30V, 10VA max. noninductive load, AC or DC |
| Enclosure: | IP65 (NEMA 4X) |
| Ambient temperatures: | 14°F to 122°F (-10°C to 50°C) |
| Output: | 4-20 mA / HART |
| Measurement: | Oxygen in flue gas |
| Company Info. |
| Xiangjing (Shanghai) M&E Technology Co., Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |
| Parameter | Specification |
|---|---|
| Measurement Principle | Zirconium oxide net oxygen measurement |
| Output Range | 0-1% to 0-100% oxygen concentration |
| Accuracy | ±0.75% of measured value or ±0.05% oxygen |
| Response Time | <5 seconds for 90% step change |
| Power Requirements | 115/230 VAC, 47-63 Hz, 600-1900 VA |
| Analog Output | 4-20 mA, 0-20 mA, or configurable |
| Alarm Configuration | Two independent oxygen alarms (high/low) |
Closed-Coupled Extraction Design: Enables fast response in high-temperature flue gas applications up to 3000°F.
Field-Serviceable Construction: Simplifies maintenance with modular components and easy sensor replacement.
Advanced Control Unit: Series 2000 controller with password protection, pressure compensation, and diagnostic logging.
High Dewpoint Tolerance: Optional configurations support sample dewpoints up to 700°F.
Robust Enclosure Options: NEMA 3R/4X weatherproof or explosion-proof enclosures for harsh environments.
Continuous Catalyst Regeneration: Optimizes oxygen control in UOP CCR processes for platinum catalyst regeneration.
Flue Gas Analysis: Monitors oxygen levels in combustion systems for emission compliance.
Industrial Gas Purification: Ensures gas purity in semiconductor manufacturing, LCD production, and inert gas systems.
Refinery & Petrochemical: Supports sulfur recovery, ethylene production, and hydrogen processing applications.
Contact Us
Phone: +8613916209596 (WeChat/WhatsApp supported)
Email: sveta@gongboshi.com
Website: https://www.shgongboshi.com/contactus.html
|