ISO75-1 ISO306 HDT VICAT softening point test apparatus for
thermoplastic materials with four frame
Summary:
ISO75-1/ISO306 four-frame HDT/VICAT softening point tester for
thermoplastics determines thermal deformation temperature and Vicat
softening point of non-metallic materials, applicable to plastics,
hard rubber, nylon, electrical insulating materials, long-fiber
reinforced composites, and high-strength thermosetting laminates.
The tester is precisely controlled via PC, with a digital dial
gauge displaying real-time deformation curves. Test results can be
printed and stored.
Product Description:
Advanced Control System
Features ultra-high stability for easier installation, testing, and
analysis.
Humanized Software Control
Touch screen displays temperature and displacement, enabling
central data management and test report printing.
Four-Layer Safety Protection
Integrates multiple hardware/software safety designs (mechanical
upper temperature limit switch, software overheat protection,
auto-stop on test completion, and administrator operation keys) to
ensure safe, stable operation.
High-Precision Measurement & Control
Utilizes high-performance temperature sensors and advanced
capacitive grid digital dial gauges for precise small-deformation
measurement. Employs advanced PID algorithms and fully
optoelectronic isolated phase modulation modules for temperature
control, ensuring heating rate error <0.5℃.
Electric Lifting Function
Despite a horizontal structure, it adds an electrically driven
specimen rack lifting function to prevent hidden damage from manual
rack operation.
Test Standards:
ISO75-1, ISO306, GB/T8802, GB/T1633, GB/T1634, ASTM D 1525-1991,
ASTM D648-06
Technical Parameters:
| Model | XRW-300BT-Ⅲ |
| 1)Temperature control range | Room temperature ~300℃ |
| 2)Maximum temperature error | ±0.5℃ |
| 3)Heating rate | 50℃/h,120℃/h,Or set between 50-120℃ / h |
| 4)Temperature measurement point | 1 |
| 5)Test frame number | 3 |
| 6)The range of deformation measurement | -0.1~10mm |
| 7)Maximum deformation error | ±0.005mm |
| 8)Deformation resolution | 0.001mm |
| 9)The sample supports the span | 64mm,100mm |
| 10)Load bar and press (needle) weight | 74g |
| 11)Voltage and power | 220V, 4KW |
| 12Thermal expansion coefficient of sample itself | <0.005/100℃ |
| 13)working medium | Methylsilicone oil or transformer oil |
| 14)cooling-down method | Natural cooling above 150℃, water cooling below 150℃ or natural
cooling. |
Support and Services:
The HDT VICAT Testing Machine is a precision instrument for
determining the deflection temperature and softening point of
thermoplastics under load.
Our technical support and services for the machine include:
- Installation and setup assistance
- Training on proper operation and maintenance
- Calibration services to ensure accurate test results
- Repair and maintenance to keep equipment in optimal condition
- Technical support via phone or email for any inquiries
We are dedicated to delivering the highest-level support to our
customers for their HDT VICAT Testing Machine.



