| Sign In | Join Free | My insurersguide.com |
|
| Categories | Stationary Meter Test System |
|---|---|
| Brand Name: | GENY |
| Model Number: | YC-1891G |
| Certification: | ISO, CE |
| Place of Origin: | China |
| MOQ: | 1 |
| Price: | negotiate rates |
| Payment Terms: | L/C,D/P,T/T |
| Supply Ability: | 5 sets / 1 months |
| Delivery Time: | 6~8weeks |
| Packaging Details: | Plywood cases |
| Power Supply: | AC220V ± 15% |
| Temperature: | -10°C to +40°C |
| Humidity: | 35% to 85% R.H. |
| Power of the voltage output: | Max.3*2000VA |
| Power of the current output: | Max.3*2800VA |
| Company Info. |
| Guangzhou GENY Electric Co., Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |
The YC-1891G Single-Phase Intelligent Electricity Meter Calibration
Device is a professional smart meter test system designed for
utility companies, metrology laboratories, and electricity meter
manufacturers.
It provides high-precision, stable, and fully automated electricity
meter calibration compatible with international standards and
modern smart metering technologies.
Built with wide voltage and current output ranges, excellent long-term stability, and support for multiple communication protocols, this device is ideal for smart meter verification, production testing, and laboratory-grade calibration.
Smart electricity meter calibration and verification
Single-phase meter accuracy testing
Laboratory and production line metrological evaluation
Full-function electricity meter error and performance testing
Power Supply
Voltage: AC220V ± 15%
Frequency: 50/60Hz ± 2Hz
Environmental Conditions
Operating Temperature: –10°C to +40°C
Humidity: 35%–85% R.H.
Output Voltage
Range: 0–480V
Resolution: ≤0.01V
Power: >10VA (per step)
Stability: ≤0.02% / 120s
Load Change Rate: ≤0.01%
Distortion: ≤0.3% (full linear load range)
Output Current
Range: 0–120A
Resolution: ≤0.01%
Power: >15VA (per step)
Stability: ≤0.02% / 120s
Load Change Rate: ≤0.01%
Distortion: ≤0.3% (linear load range)
Phase & Frequency
Phase Range: 0–360° (Resolution: 0.01°)
Frequency Range: 45–65Hz (Resolution: 0.01Hz)
Output Power Stability: ≤0.02% / 120s
Error Display
Signal Input: Electronic pulse or LED optical signal
Display: 8-digit LED digital display
Communication
Fully compliant with DL/T645-2007 and DL/T645-2009-001/002 standards