| Sign In | Join Free | My insurersguide.com |
|
| Categories | Digital Flow Meter |
|---|---|
| Brand Name: | Yokogawa |
| Model Number: | AXG200 |
| Place of Origin: | China |
| MOQ: | 1 pc |
| Price: | USD 1500 |
| Payment Terms: | T/T |
| Supply Ability: | 100 pc |
| Delivery Time: | 7-14 days |
| Protection Rating: | IP65, IP67, IP68 |
| Certifications: | ATEX, IECEx, SIL2 |
| Wetted Material: | Stainless Steel |
| Operating Temperature: | -40°C to 85°C |
| Ingress Protection: | IP67 |
| Voltage: | 1-5 (V) |
| Model: | XY180 |
| Mounting: | Direct or remote |
| Pressure Type: | Gauge Pressure |
| Protocol: | HART/RS485 |
| Signal Output: | 4-20mA 0-20mA 1-5V 0-5V |
| Housing Material: | Stainless steel |
| Response Time: | ≤ 5 ms |
| Mounting Method: | DIN rail or wall mount |
| Company Info. |
| Xi'an Xiyi Central Control Technology Co., Ltd. |
| Verified Supplier |
| View Contact Details |
| Product List |
Introduction
The ADMAG TI Series AXG (including the AXG200 size) is an advanced
electromagnetic (magnetic) flowmeter designed for industrial
process lines.
“AXG200” indicates a nominal size of 200 mm (8 in) for that particular variant.
Key aspects include:
Short Specification Table
Category | Specification / Description |
Manufacturer | Yokogawa |
Model | ADMAG AXG200 |
Type | Electromagnetic (magnetic) flowmeter |
Nominal Size | DN 200 (8 in) |
Measurement Principle | Faraday’s law – voltage induced by conductive fluid in a magnetic field |
Size Range of Series | 2.5 to 500 mm (0.1″ to 20″) for AXG series in general |
Lining Materials | PFA (fluorocarbon) or Ceramics tube |
Electrode Materials | Various options (e.g., stainless steel 316L, nickel alloy, tantalum, platinum-iridium) |
Accuracy (typical) | ±0.3% of rate (standard) ; high accuracy option ±0.15% (for certain sizes) |
Process Connection | ASME, EN, JIS etc flange/wafer types—various specifications |
Key Features | Dual-frequency excitation; built-in diagnostics; modern comms (HART, FOUNDATION, PROFIBUS, EtherNet/IP) |
Applications | Industrial liquids with conductivity; large pipelines; process conditions with disturbance/slurry etc |
Limitations / Notes | Fluid must be conductive; selection of liner/electrode must match fluid corrosion/abrasion; ensure correct size & installation |
.
|