| Sign In | Join Free | My insurersguide.com |
|
| Categories | Stationary Meter Test System |
|---|---|
| Brand Name: | GENY |
| Model Number: | YC-1893R |
| Certification: | ISO, CE |
| Place of Origin: | China |
| MOQ: | 1 |
| Price: | negotiate rates |
| Payment Terms: | T/T, L/C, D/P, T/T |
| Supply Ability: | 5 sets / 1 months |
| Delivery Time: | 6~8weeks |
| Packaging Details: | Plywood cases |
| Structure: | All-in-one |
| Usage: | Energy Meter Calibration, Lab Research |
| Ambient Temperature: | -10℃ to +40℃ |
| Power Supply: | 3P4W 3×380V±10%, 50Hz±2Hz |
| Ambient Humidity: | 35% to 85% R.H. |
| Voltage Resolution: | 0.001% |
| Company Info. |
| Guangzhou GENY Electric Co., Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |
Power Supply / Electrical System
| Voltage | 240/415 V AC supply (+5% & -10%) or customized |
| Frequency | 50/60Hz ±2Hz |
| Power capacity | > 3 × 6kVA |
| Ambient temperature | -10°C … +40°C |
| Relative humidity | 35% … 95% |
| System Grounding | Neutral solidly grounded |
| Surge protection level | ≥ 10 kV/120 Joules (10/1000µs) |
Power source
| Voltage | |
| Test voltage output (Phase-Neutral) | 3× (24V – 500V) or customized |
| Power of the voltage output | 3×100VA |
| Resolution | Better than 0.01% of full scale value of range |
| Setting accuracy | Better than 0.05% at the final range value |
| Stability | Better than 0.005%/h (integration time 150 s) |
| Load regulation from 0-max. load | < 0.01% |
| Distortion factor | < 0.3% for linear resistance load |
| Harmonics | 2nd – 21st free programmable |
| Current | |
| Test current output | 3× (1mA – 120A) |
| Power of the current output | 3×150VA |
| Resolution | Better than 0.01% of full scale value of range |
| Setting accuracy | Better than 0.05% at the final range value |
| Stability | Better than 0.005%/h (integration time 150 s) |
| Load regulation from 0-max. load | < 0.01% |
| Distortion factor | < 0.3% for linear resistance load |
| Harmonics | 2nd – 21st free programmable |
| Phase angle | |
| Range | 0 -- 360° |
| Resolution | 0.01° |
| Setting accuracy | 0.1° |
| Frequency | |
| Range | 45Hz – 65Hz |
| Resolution | 0.01Hz |
Reference Standard
| Power supply | |
| Voltage | AC220V ±10% |
| Frequency | 50Hz ±2Hz |
| Max power consumption | 45VA |
| Using condition | |
| Environment temperature | 10ºC … 30ºC |
| Relative humidity | 45% … 75% |
| Outside magnetic intensity | ≤ 0.025mT |
| Frequency range | 45Hz … 65Hz |
| Test current | |
| Range | 1mA … 120A |
| Error | - ±0.02% (50mA…120A) (relative measurement value) - ±0.05% (1…50mA) (relative range full-scale value) |
| Current display range | 1.000mA … 120.000A (1A, 10A, 100A) |
| Test voltage | |
| Range | 50V … 480V (auto range) |
| Error | - ±0.02% (50V…480V) (relative measurement value) - ±0.05% (5V…50V) (relative measurement value) |
| Voltage display range | 50.000(V) … 480.000(V) |
| Power measure error | |
| Active power | +0.02% (relative measurement value) 50V … 480V, 0.05A … 120A |
| Reactive power | +0.05% (relative measurement value) 50V … 480V, 0.05A … 120A |
| Apparent power | +0.05% (relative measurement value) 50V … 480V, 0.05A … 120A |
| Test Power Factor(PF=P/F) Error: 0.05% | |
| Display range | -1.00000 … +1.00000 |
| Energy constant | CH=109 imp/kWh (1A & 0.1A step) CH=108 imp/kWh (10A step) CH=107 imp/kWh (100A step) |
| Measuring modes | - 4 wire active/ reactive/ cross-connect reactive - 3 wire active/ reactive/ cross-connect reactive - 2 wire active/ reactive |
| Energy pulse input | |
| Frequency | 0.5kHz |
| Voltage | 24V |
| Measurement range of input | |
| Output | TTL pulse, load > 2kΏ |
| Dimensions (W * H * D) | 131mm * 432mm * 470mm |
| Weight | 16kgs |
The MTS have features as below
- Supporting parallel communication port to test smart meters through RS232 / Ethernet
- Calibrating terminals on the rack for test bench verification
- 1-phase energy meter for testing
- 3-phase energy meter for testing
- Accuracy Testing of reference standard meter
- Pre-warming
- Accuracy test as per IEC
- Creeping test
- Starting current test
- Repeatability of error test
- Dial test
- Influence quantity test related to accuracy tests (Voltage, Frequency, reverse phase sequence, voltage unbalance)
- Influence of harmonic component in voltage and current circuit as per IEC
- Tamper and Fraud Monitoring
- Sub Harmonics as per IEC standards (IEC 62052-11 / 62053-21/22/23)
- Odd Harmonics as per IEC standards

|