| Sign In | Join Free | My insurersguide.com | 
              
  | 
      
| Categories | Laser Gas Analyzer | 
|---|---|
| Stock: | 1PC | 
| MOQ: | 1PC | 
| Price: | USD 10000-20000 PC | 
| Payment Terms: | T/T, Western Union, Paypal | 
| Shipping Method: | LCL, AIR, FCL, Express | 
| Model: | KF200 | 
| Power Supply: | 220V AC/Costomize | 
| Ambient Temperature: | -30 ~ +60 Degree | 
| Storage Temperature: | -40 ~+80 Degree | 
| Installation Method: | In-Situ or Pass-by | 
| Explosion-Proof: | Exdiict6 | 
| EMC: | IEC 6100-4-2, IEC 6100-4-3, IEC 6100-4-4 | 
| Protection Levels: | IP66 | 
| Company Info. | 
| Nanjing Kelisaike Safety Equipment Co., Ltd. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
Tdlas Technology Integrated Laser Gas Analyzer for High Corrosion Environment
Product Description
KF series Laser Gas Analyzer developed aiming at the industrial on-line analyzing, environmental on-line monitoring.
Many types of the KF series Laser Gas Analyzer are available, including in-situ probe, by - pass type, multi-channel and Disc mounted type etc.Gas types like O2,CO,NH3,CO2,CH4,H2O,HC, HF etc. can be analyzed. The concentration analyzing of target gases contains the macro-analysis and micro-analysis.



Features
1. Adopting the TDLAS technology, the in-situ online gas analyzing
2. Double proof probe design, without positive pressure purge, no
additional data processing unit, simple compact structure, high
reliability
3. Using high-power lasers, no fiber coupling, anti-hash working
conditions (such as excessive dust condition)
4. Using patented technology of spot light path adjustment, easy
for on-site installation
Technical Specifications
| Measurement Principle | Tunable Laser Absorption Spectroscopy(TDLAS) | |
| Technical Data | linearity error | ≤±1%F.S. | 
| Span drift | ≤±1%F.S./6 months | |
| Repeatability | ≤1% | |
| calibration period | ≤1 time/6 month | |
| Explosion-proof Grade | ExdIICT6 Gb | |
| Protection levels | IP66 | |
| Response Time | Warming-up time | ≤15 min | 
| Response time(T90) | ≤8~10s | |
| Interface Signals | Analog outputs | 2-wire 4-20mA signal input(Isolated, maximum load 750Ω) | 
| Analog inputs | 2-way 4-20mA input( temperature-pressure compensation) | |
| digital outputs | RS485/RS232/GPRS | |
| Relay output | 3-wire relay(24V,1A) | |
| Operating Conditions | Ambient temperature | -30ºC~+60ºC | 
| Gas jet | 0.3~0.8MPa Industrial nitrogen inlet and purification instrument gases etc.  | |
| Power | 220VAC,power is base on specific configuration | |
| Installation | Installation Method | Sampling probe is mounted in the flue / pipe,system is installed nearby  | 
Main Process Line

Gas Detection Limits
| Detection Gas Type | Detection Limit | Detection range | 
| O2 | 0.01%Vol. | (0-1)%Vol., (0-100)%Vol. | 
| CO2 | 10 ppm | (0-1000)ppm,(0-100)%Vol. | 
| H2S | 20 ppm | (0-2000) ppm, (0-100)%Vol. | 
| HCl | 0.1 ppm | (0-50) ppm,(0-100)%Vol. | 
| NH3 | 0.1 ppm | (0-10) ppm, (0-100)%Vol. | 
| C2H2 | 0.1ppm | (0-10) ppm, (0-100)%Vol. | 
| CO | 10 ppm | (0-1000)ppm, (0-100)%Vol. | 
| H2O | 0.3 ppm | (0-50)ppm, (0-100)%Vol. | 
| HF | 0.02 ppm | (0-5)ppm, (0-10000) ppm | 
| 0.3 ppm | (0-30)ppm, (0-1)%Vol. | |
| CH4 | 0.4 ppm | (0-40)ppm, (0-100)%Vol. | 
| C2H4 | 0.6 ppm | (0-60)ppm, (0-100)%Vol. | 
Remark1:The test conditions for 1m optical path, the gas pressure
1bar, gas temperature 300K
Remark2:By increasing the optical path, proportionally lower
detection limit
                                 
                             |