| Brand Name: | ANTSPACE |
| Model Number: | ANTSPACE HK3 |
| MOQ: | 1 |
| Price: | Negotiable |
| Payment Terms: | L/C, T/T, Western Union |
| Supply Ability: | 100 |
| Delivery Time: | Shipping Date: July 1-31, 2022 |
| Packaging Details: | Dimensions (L*W*H) (mm) 6058*2438*2896 |
| Company Info. |
| Meta Miner |
| View Contact Details |
| Product List |
| Product Overview | |
| Version | ANTSPACE HK3 |
| Dimensions (L*W*H) (mm) | 6058*2438*2896 |
| Miner Capacity | 210 units -S19 Hyd. Series miner |
| Container Certification | China Classification Society Certification |
| Safety Certification | North America/Standards:NFPA 79:2021,UL 508A:2018 R8.21, CSA C22.2 No. 14-18,ANSI/ISO 12100:2012 EU/Standards:EN ISO 12100,EN 60204-1 |
| Operating Power(kW) | 1047~1050 |
| PUE(Power Usage Effectiveness) | 1.022(Excluding cooling tower)/1.036(Including cooling tower) |
| Input Voltage and Frequency | 415V±5% 60Hz(North America) 400V±5% 50Hz(EU,Middle East) |
| Detailed Characteristics | |
| Shipping Weight(T) | 8 |
| Operating Weight (T) | 12 |
| Main Switch of Power Distribution Cabinets(A) | 1200(North America) 1250(EU,Middle East) |
| Rated Current(A) | 952 |
| Standard Power(kW) | 1049 |
| Maximum Power(kW) | 1050 |
| Rated Current per Miner(A) | 10 |
| Inlet Cable | The inlet cables can withstand high-voltage of above 600V, with the following requirements per phase: L1 single core cable 600kcMil(300mm²)x4 L2 single core cable 600kcMil(300mm²)x4 L3 single core cable 600kcMil(300mm²)x4 N Single-core cable 600kcMil(300mm²)x4 PE single-core cable 500kcMil(240mm²)x2 |
| Connection Interface(Cooling Tower) | DN125(GB/T 9119-2010 PN16 DN125) |
| Connection Interface(Plate Heat Exchage Interface) | DN100(GB/T 9119-2010 PN16 DN100) |
| Flow Rate(m³/h) | >85 |
| Quantity of ANTSPACE powered by one 2500kVA Transformer | 2 |
| Product Overview | ||
| Type | Dry-Wet Tower Traditional Type (DWT-T) | Dry-Wet Tower Container Type (DWT-C) |
| Dimensions(L*W*H)(mm) | 5800*2240*4200 | 6058*2438*2896 |
| Heat Dissipation Capacity(kW) | 1000 | 1000 |
| Outlet Temperature @ 28℃ Wet Bulb Temperature | 35℃ | 35℃ |
| Container Certification | None | China Classification Society Certification |
| Safety Certification | North America/Standards: NFPA 79:2021, UL 508A:2018 R8.21, CSA C22.2 No. 14-18, ANSI/ISO 12100:2012 EU Standards: EN ISO 12100, EN 60204-1 | North America/Standards: NFPA 79:2021, UL 508A:2018 R8.21, CSA C22.2 No. 14-18, ANSI/ISO 12100:2012 EU Standards: EN ISO 12100, EN 60204-1 |
| Operating Power(kW) | 14~28 | 14~28 |
| Motor Rated Voltage and Frequency | 415V±5% 60Hz(North America) 400V±5% 50Hz(EU,Middle East) | 415V±5% 60Hz(North America) 400V±5% 50Hz(EU,Middle East) |
| Detailed Characteristics | ||
| Shipping Weight(T) | 5 | 6 |
| Operating Weight(T) | 9 | 10 |
| Connection Interface(Container) | DN125(GB/T 9119-2010 PN16 DN125) | DN125(GB/T 9119-2010 PN16 DN125) |
| Water Resupply Pipe Interface | DN40(Internal thread) | DN40(Internal thread) |
| Drain Pipe Interface | DN65(Internal thread) | DN65(Internal thread) |
| Noise Level @25℃, 16m | 70dBA | 70dBA |
| Water Consumption(m³/h) | 1~1.5 | 1~1.5 |
| Environmental Requirements | |
| 1 | Cooling tower is required to be placed on flat ground, horizontal degree (±1 degree). |
| 2 | The ground surfaced is required to be hardened and stable, able to withstand at least 14-ton load. |
| 3 | A 10-ton crane is needed for unloading ANTSPACE and cooling tower. |
| 4 | Add-on items such as stairs, transformers, cables, bridge racks and cable distribution boxes are not included in the delivery of ANTSPACE. BITMAIN team can provide design suggestions if needed. |
| 5 | Client needs to confirm the opening directon of container and it needs to face air-intake. Door on left is current design by defult. |
| 6 | Keep at least 2 meters of air in-take space around the cooling tower. |
| 7 | Altitude: ≤3000m. If the altitude is higher than 1000-meter, transformer and switch should be derated, the total power of ANTSPACE must be decreased by 1% for each elevation increment of 100 meters. |
| 8 | Operating temperature: -25°C to 40°C. Operating humidity: 10%RH to 90%RH. When the initial coolant temperature is below 20 °C, the internal circulation should be turned on to heat up the coolant to above 20 °C before starting the mining machine. |
| 9 | When the ambient temperature is below 5 ℃, the cooling tower can be switched to cold-dry mode. |
| 10 | Choose pure water or suitable antifreeze as coolant based on local climate conditions. |
| 11 | The suitable ambient temperature for ANTSPACE does not represent the suitable ambient temperature for mining machine. |

|