| Sign In | Join Free | My insurersguide.com | 
 | 
| Categories | Mobile Transformer Substation | 
|---|---|
| Brand Name: | Tianan Electric | 
| Model Number: | CZBT1-132 | 
| Certification: | IEC | 
| Place of Origin: | CHINA | 
| MOQ: | 1 unit | 
| Price: | Pending | 
| Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram | 
| Supply Ability: | 10000 units/year | 
| Delivery Time: | 45 days | 
| Packaging Details: | Wooden Carton | 
| Frequency: | 50Hz | 
| Special Conditions: | Depends on The Customer | 
| System Voltage: | 132KV 145Kv | 
| Capacity: | 16000KVA | 
| Sound level: | ≤65 dB | 
| Protection accuracy: | 5P20 | 
| Company Info. | 
| Ningbo Tianan (Group) Co.,Ltd. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
Promotional Various Durable Using Power Transformer Mobile Compact Substation
* Carefully Selected Materials
The shell is made of stainless steel, aluminum alloy, cold-rolled
plate, color steel plate, tiled, wooden strip, etc., and has good
insulation, sealing and excellent heat resistance.
* With Major Brands
Effective control and protection system, fast installation and
operation, superior performance.
* High Quality
The internal wiring is neatly arranged, the loss is low, and the
heat dissipation performance is strong, which can be used in
different environments.
* Long Service Life Of Equipment
The use of automated equipment to ensure accurate product size,
production and production in strict accordance with international
standards, maintenance-free during the period, the quality is more
guaranteed.
Service condition
1 Ambient condition
a. Altitude ≤ 1000m;
b. Ambient temperature
Range of temperature: -25℃~+40℃;
c. Wind speed (outdoor) ≤ 35m/s;
d. Relative humidity ≤ 90%(+25℃);
e. Installation spot
The place shall have no fire, explosion, chemical corrosion and exquisite vibration.
2 Move condition of the substation
a. Max. speed ≤ 30km/h,when road surface is flat;
b. Max. speed ≤ 10km/h, when road surface is not flat.
Note: If the above condition can’t satisfy requirements, customer can consult with manufacturer to resolve it.
Table1
| No. | Item | Unit | Parameter | 
| 1 | System voltage | kV | 132 | 
| 2 | Rated voltage | kV | 145 | 
| 3 | Rated frequency | Hz | 50 | 
| 4 | Rated current | A | 2000 ,1600 | 
| 5 | Rated 1min power frequency withstand voltage | kV | 275 | 
| 6 | Rated lightning impulse withstand voltage | kV | 650 | 
| 7 | Rated short time withstand current | KA | 25,31.5,40 | 
| 8 | Rated short time withstand time | s | 3 | 
| 9 | Rated peak withstand current | kA | 63,80,100 | 
| No. | Item | Unit | Parameter | ||
| 1 | System voltage | kV | 132 | ||
| 2 | Rated voltage | kV | 145 | ||
| 3 | Rated frequency | Hz | 50 | ||
| 4 | Rated current | A | 2000 | ||
| 5 | Rated 1min power frequency withstand voltage | kV | 275 | ||
| 6 | Rated lightning impulse withstand voltage | kV | 650 | ||
| 7 | Rated short time withstand current / time | KA/s | 40/4 | ||
| 8 | Rated peak withstand current | kA | 100 | ||
| 9 | Rated short circuit breaking current | kA | 40 | ||
| 10 | Rated short circuit making current | kA | 100 | ||
| 11 | DC component | % | 40 | ||
| 12 | Rated operation sequence | O 0.3s CO 180s CO | |||
| 13 | Opening time | ms | 35±5 | ||
| 14 | Closing time | ms | 105±15 | ||
| 15 | Breaking time | ms | ≤60 | ||
| 16 | Non-simultaneity between poles | Closing | ms | ≤5 | |
| Opening | ms | ≤3 | |||
| 17 | Fracture no. of each pole | 1 | |||
| 18 | Mechanical endurance | Times | ≥6000 | ||
| 19 | Full capacity continuous breaking times | Times | ≥20 | ||
| 20 | SF6 gas pressure (20℃) | Rated value | MPa | 0.60 | |
| Alarm value | MPa | 0.55 | |||
| Locking value | MPa | 0.50 | |||
| 21 | SF6 gas moisture content(μl/l) | Acceptance value | PPm | ≤150 | |
| Operation allowable value | PPm | ≤300 | |||
| 22 | SF6 yearly gas leakage rate | % | ≤0.5 | ||
| 23 | Total weight of each circuit breaker | kg | 2000 | ||
Table3 table4 Parameters of current transformer
| Rated primary current | 150,300,500,750,1000,1500,2000 | 
| Rated secondary current | 5A | 
| Rated output capacity and accuracy level | See table 4 | 
| Current ratio | Rated output capacity VA | Measure accuracy level | Protection accuracy level | 
| 150/5 300/5 500/5 750/5 1000/5 1500/5 2000/5 | 20 20 30 30,40 40,50 50 50 | 0.5 0.5 0.5 0.5 0.5 0.5 0.5 | 5P20 5P20 5P20 5P20 5P20 5P20 5P20 | 
Note: (1) Straight-through type bushing current transformer is attached in the circuit breaker.
Table5 Parameters of lightning arrester
| No. | Item | Unit | Parameter | 
| 1 | System voltage | kV | 132 | 
| 2 | Rated voltage | kV | 150 | 
| 3 | Rated frequency | Hz | 50 | 
| 4 | Nominal discharge current | kA | 10 | 
| 5 | DC 1mA reference voltage | kV | ≥245 | 
| 6 | Residual voltage under lightning impulse current (peak) | kV | ≤435 | 
| 7 | Residual voltage under operation impulse current (peak) | kV | ≤370 | 
| 22 | Residual voltage under steep wave impulse current (peak) | kV | ≤490 | 
Table 6 Parameters of neutral point lightning arrester
| No. | Item | Unit | Parameter | 
| 1 | System voltage | kV | 132 | 
| 2 | Rated voltage | kV | 90 | 
| 3 | Rated frequency | Hz | 50 | 
| 4 | Nominal discharge current | kA | 1.5 | 
| 5 | DC 1mA reference voltage | kV | ≥140 | 
| 6 | Residual voltage under lightning impulse current (peak) | kV | ≤260 | 
| 7 | Residual voltage under operation impulse current (peak) | kV | ≤240 | 
| 8 | Residual voltage under steep wave impulse current (peak) | kV | / | 
Table7 Technical parameters of switch equipment on LV side
| No. | Item | Unit | Parameter | 
| 1 | System voltage | kV | 11.5 | 
| 2 | Rated voltage | kV | 12 | 
| 3 | Rated frequency | Hz | 50 | 
| 4 | Rated current | A | 2000,1600,1250, | 
| 5 | Rated 1min power frequency withstand voltage | kV | 42/48 | 
| 6 | Rated lightning impulse withstand voltage | kV | 75/85 | 
| 7 | Rated short time withstand current | kA | 40,31.5,25 | 
| 8 | Rated short time withstand time | s | 4 | 
| 9 | Rated peak withstand current | kA | 100,80,63 | 
| 10 | Rated short circuit breaking current | kA | 40,31.5,25 | 
| 11 | Rated short circuit making current | kA | 100,80,63 | 
| 12 | Rated operation sequence | O 0.3s CO 180s CO | |
| 13 | Mechanical endurance | Times | ≥10000 | 

|   | 
 132KV Mobile Transformer Substation / Distribution Movable Power Substation
                                                                                    
                        
                        
                        
                                                            132KV Mobile Transformer Substation / Distribution Movable Power Substation
                                                    
                        
                     132 Kv Vehicle Mounted Transformer Substation /  Prefabricated Mobile Substation
                                                                                    
                        
                        
                        
                                                            132 Kv Vehicle Mounted Transformer Substation /  Prefabricated Mobile Substation
                                                    
                        
                     Prefabricated 132KV  Semi-trailer Vehicle-mounted Mobile Substation
                                                                                    
                        
                        
                        
                                                            Prefabricated 132KV  Semi-trailer Vehicle-mounted Mobile Substation
                                                    
                        
                     132kv Prefabricated Mobile Vehicle Mounted semi-trailer Transformer Substation
                                                                                    
                        
                        
                        
                                                            132kv Prefabricated Mobile Vehicle Mounted semi-trailer Transformer Substation
                                                    
                        
                     132kv Outdoor Distribution Emergency Power Mobile Transformer Substation
                                                                                    
                        
                        
                        
                                                            132kv Outdoor Distribution Emergency Power Mobile Transformer Substation
                                                    
                        
                     Vehicle Borne Mobile Transformer Substation Prefabricated 110 - 132 Kv
                                                                                    
                        
                        
                        
                                                            Vehicle Borne Mobile Transformer Substation Prefabricated 110 - 132 Kv
                                                    
                        
                     132kv Prefabricated Mobile Transformer Substation Emergency Vehicle Mounted
                                                                                    
                        
                        
                        
                                                            132kv Prefabricated Mobile Transformer Substation Emergency Vehicle Mounted
                                                    
                        
                     16kv Prefabricated Mobile Transformer Substation Electrical Power Substation
                                                                                    
                        
                        
                        
                                                            16kv Prefabricated Mobile Transformer Substation Electrical Power Substation
                                                    
                        
                     132kv Mobile Transformer Substation
                                                                                    
                        
                        
                        
                                                            132kv Mobile Transformer Substation
                                                    
                        
                     132kv Prefabricated Distribution Transformer Substation  Explosion Proof
                                                                                    
                        
                        
                        
                                                            132kv Prefabricated Distribution Transformer Substation  Explosion Proof