| Sign In | Join Free | My insurersguide.com | 
 | 
| Categories | Energy Efficiency Lab | 
|---|---|
| Brand Name: | Sinuo | 
| Model Number: | SN331-30K BTU | 
| Certification: | Calibration Certificate (Cost Additional) | 
| Place of Origin: | China | 
| MOQ: | 1 | 
| Price: | Tailored | 
| Payment Terms: | T/T | 
| Supply Ability: | 1 Set Per Month | 
| Delivery Time: | 2 Months | 
| Packaging Details: | Plywood | 
| Applied Standards: | ISO 5151, ISO 13253 , etc. | 
| UUT: | Household Air Conditioners | 
| Cooling Capacity: | 6000~30000Btu/h | 
| Heating Capacity: | 6000~30000Btu/h | 
| Indoor Temperature: | 10 ° C~50 ° C | 
| Outdoor Temperature: | -20 ° C~60 ° C | 
| Indoor Humidity: | 35%~90% | 
| Outdoor Humidity: | 25%~90% | 
| Company Info. | 
| Sinuo Testing Equipment Co. , Limited | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
30K BTU Single Code Test Laboratory Air Enthalpy Method Calorimeter
System overview
This air enthalpy method calorimeter lab designed and manufactured by consists of 1 indoor side room(Room A)and 1 outdoor side room(Room B). The refrigerating capacity, heating capacity and other performances of an air conditioner are tested by means of testing the lab parameters, such as temperature, pressure and electrical performance. This installation can be used to test the performance of various window type, split type, free-standing type and ceiling cassette type and duct type AC air conditioners, and can also be used for other standard operating condition related tests and expanded tests, meeting the need for product sampling inspection and product development. The laboratory is equipped with one station, which can test 1 set of 3-Phase prototypes not larger than 30KBtu.
In this test system, the operation of the equipment is controlled by a programmable controller and a HMI, test running data are collected by a high accuracy data collector, the data can be transferred at real time to an upper level computer for processing, the computer displays, stores, outputs and prints test reports.
According to standards
Design and Testing according to the following standards:
► ISO 5151:2010, ISO 13253
► IEC 60335-2-40
► JISB 8615, JISB8616
Types of UUT
-Split type
-Window type
-Free-standing type
-Ceiling cassette type
-Duct type
-Inver-frequency air condition
Test contents
► Rated cooling capacity (T1, T2, T3).
► Rated heating capacity (High, Low, Extra-low)
► Airflow
► Dehumidification capacity
► Input power
► EER(COP)
► Frequency
► Current
► Voltage
Measurement Accuracy and Repeatability
| Measurement accuracy | Repeatability accuracy | |
| Testing method | Compared with standard machine | Average deviation from 3 tests once installed | 
| Items | ||
| Cooling capacity | ±2% beneath | ±1% beneath | 
| Heating capacity | ±2% beneath | ±1% beneath | 
Chamber dimensions
► External dimensions (mm): 12500W×4000D×3500H; (Contain Control room & Machine room)
-Room A (30K Indoor side room) dimensions (mm): 5000W×4000D×3500H;
-Room B (30K Outdoor side room) dimensions (mm): 4000W×4000D×3500H;
► Materials: δ=100mm rigid polyurethane foam insulation, 0.6t color steel plate on inside and outside walls and ceiling, ID Room 2.5t stainless steel floor covered with 0.6t color steel plate, OD Room 3.0t stainless steel floor covered with 0.6t color steel plate.
► Doors: Single door (mm): 1200W×2500H,(2 set);
► View windows(mm): 400W×500H,(2 set)

|   | 
 IEC 60879-2019 Energy Efficiency Lab Ceiling Fans Environmental Test Chamber
                                                                                    
                        
                        
                        
                                                            IEC 60879-2019 Energy Efficiency Lab Ceiling Fans Environmental Test Chamber
                                                    
                        
                     Performance Analysis Energy Efficiency Lab For Clothes Washing Machines
                                                                                    
                        
                        
                        
                                                            Performance Analysis Energy Efficiency Lab For Clothes Washing Machines
                                                    
                        
                     Energy Efficiency Testing Room For DOE Qualified Ceiling Fans UL Standard Ceiling Fan Laboratory
                                                                                    
                        
                        
                        
                                                            Energy Efficiency Testing Room For DOE Qualified Ceiling Fans UL Standard Ceiling Fan Laboratory
                                                    
                        
                     Temp. 76±2°F Humidity 50% Energy Efficiency Test Lab Of ENERGY STAR Qualified Ceiling Fans
                                                                                    
                        
                        
                        
                                                            Temp. 76±2°F Humidity 50% Energy Efficiency Test Lab Of ENERGY STAR Qualified Ceiling Fans
                                                    
                        
                     Energy Efficiency Testing Laboratory For Electric Water Storage Heaters 4 / 6 / 8/ 10 Stations
                                                                                    
                        
                        
                        
                                                            Energy Efficiency Testing Laboratory For Electric Water Storage Heaters 4 / 6 / 8/ 10 Stations
                                                    
                        
                     Air Conditioners / Heat Pumps Energy Efficiency Lab 3HP Air Enthalpy Method Calorimeter Test
                                                                                        
                                                        
                        
                        
                        
                                                            Air Conditioners / Heat Pumps Energy Efficiency Lab 3HP Air Enthalpy Method Calorimeter Test
                                                    
                        
                     IEC 60456 Washing Machines Performance Testing Room Energy Efficiency Enviromental Lab
                                                                                    
                        
                        
                        
                                                            IEC 60456 Washing Machines Performance Testing Room Energy Efficiency Enviromental Lab
                                                    
                        
                     Electric Rice Cookers Energy Efficiency Lab 2 Test Benches 6 Black Corners
                                                                                    
                        
                        
                        
                                                            Electric Rice Cookers Energy Efficiency Lab 2 Test Benches 6 Black Corners
                                                    
                        
                     Water Efficiency Grades Energy Efficiency Lab For Reverse Osmosis Drinking Water Treatment Purifiers
                                                                                    
                        
                        
                        
                                                            Water Efficiency Grades Energy Efficiency Lab For Reverse Osmosis Drinking Water Treatment Purifiers
                                                    
                        
                     10 ~ 3000m³/H 0~ 200Pa Air Volume Measurement System For A.C. Electric Ventilating Fans
                                                                                    
                        
                        
                        
                                                            10 ~ 3000m³/H 0~ 200Pa Air Volume Measurement System For A.C. Electric Ventilating Fans