| Sign In | Join Free | My insurersguide.com | 
 | 
| Categories | Digital Fundus Camera | 
|---|---|
| Brand Name: | SYSEYE | 
| Model Number: | RetiCam 3100 | 
| Certification: | FDA | 
| Place of Origin: | China | 
| MOQ: | 1 | 
| Price: | $12,000.00-$13,000.00 | 
| Payment Terms: | , T/T | 
| Supply Ability: | 100 | 
| Delivery Time: | 5 working days | 
| Packaging Details: | 380mm(L)x550mm(W)x475mm(H) | 
| Product name: | Non-dilated Digital Fundus Camera | 
| Focus adjustment range: | ±25D | 
| Weight: | 26.5Kg | 
| Field View: | 50° | 
| Working Distance: | 35mm | 
| Minimum Pupil: | ≥3.3mm | 
| Shooting light: | Auto: with shooting mode | 
| Illumination light: | Infrared led | 
| Company Info. | 
| Chongqing Bio Newvision Medical Equipment Ltd. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
ophthalmic fundus camera SLR camera one-key click 135° wide field
Digital Fundus Camera RetiCam 3100 can be used to capture the anterior and posterior eye images. It has a field of view of 50 degrees for fundus imaging.Digital Fundus Camera Reticam 3100 is a highly recognized and popular automatic fundus imaging system around the world. Through dual camera imaging, image control and feature recognition, eye XYZ 3D automatic positioning is realized. Through CCD imaging feedback, the exposure is measured, and the exposure intensity is automatically and accurately determined, without the need for a doctor's complex operation. By controlling the focusing step length according to the image resolution, the image definition can be automatically adjusted to obtain a clear and accurate fundus image and help doctors make accurate judgments for patients.
| Field of view | 50° | 
| Field of view tolerance | ±7% | 
| Resolution | |
| Center of view | ≥60 lp/mm | 
| Field of view center (r/2) | ≥40 lp/mm | 
| At the edge of the field of view (r) | ≥25 lp/mm | 
| Magnification | 1.3 times | 
| Required pupil diameter | 4.0 mm or more (3.3 mm or more when using the small pupil shooting function) | 
| Working distance | 35 mm | 
| Focus adjustment range | ±25D | 
| Shooting light | Auto: with shooting mode | 
| Manual: can be set manually | |
| light source | |
| Illumination light | Infrared led | 
| Shooting light | Xenon lights | 
| reflected light | |
| Scattered light | |
| camera | Digital camera | 
| Fixing light | Internal fixing light (LED) | 
| External fixation light | |
| Moving range | |
| Stage | 90 mm left and right, 35 mm front and rear | 
| Main unit moves vertically | 30 mm | 
| Chin-rest tray movement range | 60 mm | 
| Rated power supply | AC 100V~240V,50/60Hz | 
| size | 380 mm(L)x 550 mm(W)x 475 mm(H) | 
| weight | About 26.5kg | 
| When in maximum light intensity/hole bar state | |
| Spectral wavelength | 305 nm~1100 nm | 
| Equipment classification | ||
| Electric shock protection | Class I device | |
| Degree of electric shock protection | Type B | |
| Water-proof protection | IPX0 | |
| Safety level for use in flammable anesthetic gases, oxygen or nitrous oxide mixed with air | Not applicable | |
| Standards | ||
| GB 9706.1-2007 IEC 60601-1:1998 + A1:1991 + A2: 1995 | Medical electrical equipment - Part 1: General requirements for safety | |
| IEC 60601-1:2005 | Medical electrical equipment - Part 1: General requirements for basic safety and practical performance | |
| IEC 60601-1-1:2000 | Medical electrical equipment - Part 1-1: General requirements for safety - Parallel standard: Safety requirements for medical electrical systems | |
| IEC 60601-1-2:2001 + A1:2004 | Medical electrical equipment - Part 1-2: General requirements for safety - Parallel standard: Electromagnetic compatibility - Requirements and testing | |
| IEC 60601-1-2:2007 | Medical electrical equipment – Part 1-2: Basic safety and General requirements for practical performance – side-by-side standards: electromagnetic compatibility – requirements and testing | |
| IEC 60601-1-4:1996 + A1:1999 | Medical Electrical Equipment - Part 1-4: Safety General Seeking – Parallel Standard: Programmable Medical Electrical System | 
| IEC 60601-1-6:2010 | Medical electrical equipment - Part 1-6: General requirements for basic safety and practical performance - Parallel standard: Availability | 
| ISO 14971:2007 | Medical Devices – Risk Management for Medical Devices | 
| ISO 15004-1:2006 | Ophthalmic instruments - Test methods for basic requirements - Part 1: General requirements for all ophthalmic instruments | 
| ISO 15004-2:2007 | Ophthalmic instruments - Test methods for basic requirements - Part 2: | 
| ISO 10940:2009 | Ophthalmic Instruments - Fundus Camera | 
| ISO 10993-1:2009 ISO 10993-5:2009 ISO 10993-10:2010 | Biological evaluation of medical devices | 
| IEC 62304:2006 | Medical Device Software - Software Lifecycle Process | 
| IEC 62366:2007 | Medical Devices – Usability Engineering for Medical Devices | 
| GB/T 191-2008 | Packaging storage and transportation icon | 
| GB 4824-2013 | Industrial, scientific and medical (ism) radio frequency equipment disturbance characteristics limits and methods of measurement | 
| GB/T 14710-2009 | Medical electrical environment requirements and test methods | 
| GB/T 16886.1-2011 | Medical Device Biology Evaluation - Part 1: Evaluation and Testing in Risk Management Process | 
| GB/T 16886.5-2003 | Biological evaluation of medical devices - Part 5: In vitro cytotoxicity test | 
| GB/T 16886.10-2005 | Biological evaluation of medical devices - Part 10: Stimulation and delayed hypersensitivity test | 
| GB/T 5702-2003 | Light source color evaluation method | 
| YY 0634-2008 | Ophthalmic instrument fundus camera | 
| YY 0505-2012 | Medical electrical equipment - Part 1-2: General requirements for safety - Parallel standard: Electromagnetic compatibility - Requirements and testing | 


|   | 
 Highly Accurate Retinal Fundus Camera And Easy To Use Digital Fundus Camera
                                                                                        
                                                        
                        
                        
                        
                                                            Highly Accurate Retinal Fundus Camera And Easy To Use Digital Fundus Camera
                                                    
                        
                     High Resolution Digital Fundus Camera Minimum Pupil 3.3mm Red Free (FFA)/(FAF)
                                                                                        
                                                        
                        
                        
                        
                                                            High Resolution Digital Fundus Camera Minimum Pupil 3.3mm Red Free (FFA)/(FAF)
                                                    
                        
                     Ophthalmic Digital Fundus Camera Optic Ultra High Resolution Fully Auto
                                                                                        
                                                        
                        
                        
                        
                                                            Ophthalmic Digital Fundus Camera Optic Ultra High Resolution Fully Auto
                                                    
                        
                     FAF Red Free Digital Fundus Camera AC 100V Photography Equipment FFA
                                                                                        
                                                        
                        
                        
                        
                                                            FAF Red Free Digital Fundus Camera AC 100V Photography Equipment FFA
                                                    
                        
                     SYSEYE RetiCam 3100 Digital Fundus Camera with 1.3 Magnification 26.5Kg Weight and 90 mm Stage Movement for High Precision Retinal Imaging
                                                                                        
                                                        
                        
                        
                        
                                                            SYSEYE RetiCam 3100 Digital Fundus Camera with 1.3 Magnification 26.5Kg Weight and 90 mm Stage Movement for High Precision Retinal Imaging
                                                    
                        
                     Digital Fundus Photography Camera Machine 35mm Effective Management Of Results
                                                                                        
                                                        
                        
                        
                        
                                                            Digital Fundus Photography Camera Machine 35mm Effective Management Of Results
                                                    
                        
                     Auto Non Mydriatic Fundus Camera 3.5mm Observing Retinopathy
                                                                                        
                                                        
                        
                        
                        
                                                            Auto Non Mydriatic Fundus Camera 3.5mm Observing Retinopathy
                                                    
                        
                     50 Degrees Digital Fundus Camera Non Mydriatic Anterior Posterior Eye Images
                                                                                        
                                                        
                        
                        
                        
                                                            50 Degrees Digital Fundus Camera Non Mydriatic Anterior Posterior Eye Images
                                                    
                        
                     Retina Non Mydriatic Retinal Camera AF For Emergency Patients
                                                                                        
                                                        
                        
                        
                        
                                                            Retina Non Mydriatic Retinal Camera AF For Emergency Patients
                                                    
                        
                     High Resolution Digital Fundus Camera Red Free Retinal Imaging
                                                                                        
                                                        
                        
                        
                        
                                                            High Resolution Digital Fundus Camera Red Free Retinal Imaging