| Sign In | Join Free | My insurersguide.com | 
 | 
| Categories | Closed Loop Hall Effect Current Sensor | 
|---|---|
| Brand Name: | TOKEN | 
| Model Number: | TBC-LTH/LTR | 
| Certification: | CE;ROHS | 
| Place of Origin: | CHINA | 
| MOQ: | 10pcs | 
| Price: | Price Reconsideration | 
| Supply Ability: | 2.2K pcs per month | 
| Packaging Details: | Little Carton Size:34*23*21CM;240pcs/Carton ;Large Carton Size:48*37*26CM;480pcs/Carton | 
| application: | Uninterruptible Power Supplies | 
| Mounting Type: | PCB Mounting | 
| Principle: | null balance | 
| Standard: | high precision | 
| product name: | Hall Effect Current Sensor | 
| Operating temperature: | -40~+85 | 
High Accuracy Hall Effect Dc Current Sensor TBC-LTH/LTR Series Custom
The TBC-LTH/LTR Series current sensor is a closed loop device based on the measuring principle of the hall effect and null balance method , with a galvanic isolation between primary and secondary circuit, the size of primary doesn’t affect test precision, no matter the location of primary in the hole of current sensor, It can really measure resolution 1000:1 and uses for precision measurement of DC, AC and pulse current.
| Electrical data(Ta=25℃±5℃) | 
| Type 
 | TBC50 LTH/LTR | TBC100 LTH/LTR | TBC150 LTH/LTR | TBC200 LTH/LTR | TBC300 LTH/LTR | TBC300 LTH/LTR | Unit | 
| Rated current(Ipn) | 5-50 | 10-100 | 30-150 | 20-200 | 30-300 | 30-300 | A | 
| Measure range(Ip) | 150(±18V,82Ω) | 300(±18V,30Ω) | 450(±18V,33Ω) | 450(±18V,33Ω) | 900(±18V,3.0Ω) | 900(±18V,2.0Ω) | A | 
| Turns ratio(Np/Ns) | 1:1000 | 1:1000 | 1:1500 | 1:2000 | 1:2000 | 1:3000 | |
| 
 with ±12V | @50Amax 180(max) | @100Amax 75(max) | @150Amax 90(max) | @200Amax 90(max) | @300Amax 48(max) | @300Amax 68(max) | Ω | 
| @150Amax 40(max) | @300Amax 12(max) | @300Amax 33(max) | @600Amax 15(max) | @600Amax 10(max) | @600Amax 1.0(max) | Ω | |
| 
 with ±15V | @50Amax 240(max) | @100Amax 110(max) | @150Amax 120(max) | @200Amax 120(max) | @300Amax 70(max) | @300Amax 91(max) | Ω | 
| @150Amax 60(max) | @300Amax 20(max) | @300Amax 50(max) | @600Amax 25(max) | @600Amax 20(max) | @750Amax 2.0(max) | Ω | |
| Rated output (Isn) | 5(5A)- 50(50A) ±0.2% | 10(10A)- 100(100A) ±0.2% | 20(30A)- 100(150A) ±0.2% | 10(20A)- 100(200A) ±0.2% | 15(30A)- 150(300A) ±0.2% | 10(30A)- 100(300A) ±0.2% | mA | 
| Coil resister | 30 | 25 | 20 | 30 | 28 | 53 | Ω | 
| Supply voltage | ±12~±18 | V | |||||
| Power consumption | ≤20+IpXNs | mA | |||||
| Offset current | @Ip=0 ≤±0.2 | mA | |||||
| Offset drift | @ -40℃~85℃ ±0.5 | mA | |||||
| Response time | @100A/μS,10%-90% <1.0 | µs | |||||
| Linearity | @Ip=0-±Ipn ≤0.1 | %FS | |||||
| Galvanic isolation | @ 50HZ,AC,1min 3 | KV | |||||
| di/dt | >100 | A/µs | |||||
| Bandwidth | @ -3db DC…100 | KHz | |||||
| Applications | 
Variable speed drives
Welding machine
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Electrochemical
| Mechanical dimension(for reference only) | 

Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm
| Directions for use | 
Is will be in a forward direction when the Ip flows according to the direction of the arrowhead.
The primary conductor should be≤120℃.
The dynamic performance (di/dt and the response time) is the best when the primary hole is fully filled with the bus bar.
| Standards | 
| General date | 
| Value | Unit | Symbol | |
| Operating temperature | -40 to +85 | ºC | TA | 
| Storage temperature | -40 to +125 | ºC | TS | 
| Mass(approx) | LTH:58,LTR:64 | g | M | 
| Characteristics chart | 
Pulse current signal response characteristic Effects of impulse noise

|   | 
 PCB Mounting Closed Loop Hall Effect Current Sensor For DC Motor Drives
                                                                                    
                        
                        
                        
                                                            PCB Mounting Closed Loop Hall Effect Current Sensor For DC Motor Drives
                                                    
                        
                     0.5% Accuracy Closed Loop Current Sensor For Electromagnetic Heater And Filter Use
                                                                                    
                        
                        
                        
                                                            0.5% Accuracy Closed Loop Current Sensor For Electromagnetic Heater And Filter Use
                                                    
                        
                     Null Balance Closed Loop Hall Effect Current Sensor High Precision TBC1000LF
                                                                                    
                        
                        
                        
                                                            Null Balance Closed Loop Hall Effect Current Sensor High Precision TBC1000LF
                                                    
                        
                     AC DC Pulse Current High Frequency Current Sensor Closed Loop Current Transducer
                                                                                    
                        
                        
                        
                                                            AC DC Pulse Current High Frequency Current Sensor Closed Loop Current Transducer
                                                    
                        
                     Input Current 10-1000A Closed Loop Hall Effect Sensor Low Current Hall Effect Sensor
                                                                                    
                        
                        
                        
                                                            Input Current 10-1000A Closed Loop Hall Effect Sensor Low Current Hall Effect Sensor
                                                    
                        
                     UPS SMPS Closed Loop Hall Effect Current Sensor 2000a Measure Range
                                                                                    
                        
                        
                        
                                                            UPS SMPS Closed Loop Hall Effect Current Sensor 2000a Measure Range
                                                    
                        
                     1000A Closed Loop Hall Effect Current Sensor / Blue Dc Current Sensor
                                                                                    
                        
                        
                        
                                                            1000A Closed Loop Hall Effect Current Sensor / Blue Dc Current Sensor
                                                    
                        
                     UPS SMPS Closed Loop Hall Effect Current Sensor 2000a Measure Range
                                                                                    
                        
                        
                        
                                                            UPS SMPS Closed Loop Hall Effect Current Sensor 2000a Measure Range
                                                    
                        
                     Multi Range Closed Loop Hall Effect Current Sensor Hall Effect High Current Sensor
                                                                                    
                        
                        
                        
                                                            Multi Range Closed Loop Hall Effect Current Sensor Hall Effect High Current Sensor
                                                    
                        
                     UPS SMPS Closed Loop Hall Effect Current Sensor 2000a Measure Range
                                                                                    
                        
                        
                        
                                                            UPS SMPS Closed Loop Hall Effect Current Sensor 2000a Measure Range