| Sign In | Join Free | My insurersguide.com | 
 | 
| Categories | Single Phase Voltage Monitoring Relay | 
|---|---|
| Brand Name: | GINRI | 
| Model Number: | SVR-220 | 
| Certification: | CE | 
| Place of Origin: | China | 
| MOQ: | 20Pcs | 
| Payment Terms: | L/C, T/T, Western Union,Paypal | 
| Supply Ability: | 20000Pcs Per Month | 
| Delivery Time: | 5-8 working days | 
| Packaging Details: | 1 relay in individual box | 
| Rated Voltage: | 440V | 
| Output Contact: | 1CO | 
| functions: | overvoltage ,undervoltage | 
| Mounting: | DIN Rail | 
Over Voltage Relay SVR-220 220V 440V Voltage Control Relay Single Phase Protector
♦ Features
-- Single-phase monitoring of over- and undervoltage
-- Powered by the measuring circuit
-- 1 C/O contacts
-- 3 LEDs for status indication
♦ Protective Functions
-- Overvoltage
-- Undervoltage
♦ Typical Applications
• Pumps • Fans
• Blowers • Motors
• Compressors
♦ Approvals
• CE • CCC
♦ Technical data
| Type | SVR-220 | ||||||||||||||||||
| Measuring circuit | L,N | ||||||||||||||||||
| Rated voltage | 110VAC,220VAC ,440VAC 240VAV,250VAC,50/60Hz | ||||||||||||||||||
| Monitoring functions | overvolatege, undervoltage | ||||||||||||||||||
| Voltage setting range | 
 | ||||||||||||||||||
| Indicators | overvolatege, undervoltage, and normal | ||||||||||||||||||
| Output contacts | 1 C/O | ||||||||||||||||||
| Contact capacity | 3A ,250VAC | ||||||||||||||||||
| Dimensions (H x W x D) | 68×30×76mm | ||||||||||||||||||
| Mounting | DIN rail | ||||||||||||||||||

Electromagnetic relays are generally composed of a core, a coil, an armature, a contact spring, and the like. As long as a certain voltage is applied to both ends of the coil, a certain current flows in the coil, thereby generating an electromagnetic effect, and the armature will absorb the pulling force of the return spring against the iron core under the action of the electromagnetic force attraction, thereby driving the armature. The moving contact is in contact with the stationary contact (normally open contact). When the coil is de-energized, the electromagnetic suction force also disappears, and the armature returns to the original position at the reaction force of the spring, so that the movable contact is attracted to the original static contact (normally closed contact). This is sucked and released, thereby achieving the purpose of turning on and off in the circuit. For the "normally open, normally closed" contacts of the relay, it can be distinguished as follows: a static contact that is in an open state when the relay coil is not energized, called a "normally open contact"; a static contact that is in an on state It is a "normally closed contact".
|   | 
 DC12V Pumps Single Phase Home Voltage Protector Adjustable Reset Mode
                                                                                    
                        
                        
                        
                                                            DC12V Pumps Single Phase Home Voltage Protector Adjustable Reset Mode
                                                    
                        
                     Air - conditioning Single Phase Protection Relay , AC DC Under Voltage Monitoring Relay
                                                                                    
                        
                        
                        
                                                            Air - conditioning Single Phase Protection Relay , AC DC Under Voltage Monitoring Relay
                                                    
                        
                     50/60 Hz Single Phase Voltage Monitoring Relay DIN Rail Mounting For Compressors
                                                                                    
                        
                        
                        
                                                            50/60 Hz Single Phase Voltage Monitoring Relay DIN Rail Mounting For Compressors
                                                    
                        
                     Sequence Single Phase Under Over Voltage Relay Fault Recording With Last 3 Faults
                                                                                    
                        
                        
                        
                                                            Sequence Single Phase Under Over Voltage Relay Fault Recording With Last 3 Faults
                                                    
                        
                     Over Under  Single Phase Voltage Monitoring Relay  AC DC 48V Rated Voltage
                                                                                    
                        
                        
                        
                                                            Over Under  Single Phase Voltage Monitoring Relay  AC DC 48V Rated Voltage
                                                    
                        
                     Time delay Overvoltage Monitoring Relay , SVR1000 Voltage Detection Relay
                                                                                    
                        
                        
                        
                                                            Time delay Overvoltage Monitoring Relay , SVR1000 Voltage Detection Relay
                                                    
                        
                     220V Digital SVR Single Phase Voltage Monitoring Relay 1CO / 1NC Contacts
                                                                                    
                        
                        
                        
                                                            220V Digital SVR Single Phase Voltage Monitoring Relay 1CO / 1NC Contacts
                                                    
                        
                     AC DC  Elevators  Single Phase Home Voltage Protector Automatic With Power - On Delay
                                                                                    
                        
                        
                        
                                                            AC DC  Elevators  Single Phase Home Voltage Protector Automatic With Power - On Delay
                                                    
                        
                     Fans 250VAC Single Phase Voltage Monitoring Relay SVR-W 68 × 30 × 76 mm
                                                                                    
                        
                        
                        
                                                            Fans 250VAC Single Phase Voltage Monitoring Relay SVR-W 68 × 30 × 76 mm
                                                    
                        
                     Single Phase Overvoltage Protection Relay 35mm Din rail Mounting For Refrigeration
                                                                                    
                        
                        
                        
                                                            Single Phase Overvoltage Protection Relay 35mm Din rail Mounting For Refrigeration