| Sign In | Join Free | My insurersguide.com |
|
| Categories | Air Quality Monitoring Sataion |
|---|---|
| Brand Name: | Eyesky |
| Model Number: | ES80A-Y8 |
| Certification: | CE,ROSH |
| Place of Origin: | CHINA |
| MOQ: | 1 |
| Payment Terms: | L/C, T/T, Western Union, MoneyGram |
| Delivery Time: | 5-8 days |
| Test item: | Dust, Noise, Meteorological factors |
| Power supply: | 220V 50HZ |
| Display: | LED Screen |
| Application: | Environmental Monitoring |
| Preheat time: | 60s |
| Working Temperature: | -20℃~50℃ |
| Detection method: | Pump |
| Mode of data transmission: | RS485 Modbus,GPRS |
ES80A Technical requirements for environmental noise automatic monitoring system
ES80A-Y8 Dust online monitoring system it’s the featured product by Shenzhen Eyesky in 2018 , it can monitor the parameter of the ambient environment like PM2.5,PM10,TSP,temperature and humidity , wind speed , wind direction , air pressure etc . Combined with the industrial laser sensor technical and the unique Heating dehumidification compensation device , reduce the reflection of the test result by temperature and humidity during the particle monitoring .
Basic parameter
| Name of product | Dust online monitoring system |
| Products type | ES80A-Y8 |
| Detection method | Pump |
| Monitor parameter | PM2.5, PM10, TSP(optional), wind speed, temperature and humidity , air pressure , noise ; video monitor (optional). |
| Mode of data transmission | RS485 Modbus,GPRS |
| Preheat time | 60s |
| Material | cold-roll steel sheets |
| Installation type | column and wall hanging is optional |
| Temperature | -20℃--50℃ |
| Humidity | 5%RH -95%RH |
| Storage temperature | -30℃--70℃ |
| Power supply | AC220V/50Hz or solar |
| Power consumption | Humidity less than 90%RH,<20W; Humidity more than 90%RH,<60W, |
| Protection grade | IP55 dust-proof ,water-proof |
| Dimension | 430mm*160mm*600mm |
Technical parameters of particle monitoring are as follows:
| Major parameter of the particle | Technical standard |
| Measuring range | PM2.5(0-10)mg/m3,PM10(0-10)mg/m3 |
| Sampling flow | 1.3L/min,precision±3%,Equipped with cyclone physical cutter |
| Sampling time | Adjustable, default 5 minutes |
| Particle diameter | PM2.5,PM10, TSP(optional) |
| Resolution ratio | 1ug/m3 |
| Heat inlet | Dynamic heating and dehumidification according to ambient humidity |
| Fault alarm | Real-time display fault alarm |
| Excessive linkage | Optional linkage fog gun machine device |
Meteorological technical parameters are as follows:
| Meteorological module | Measuring range | Precision | Resolution |
| Wind speed | 1~60m/s | ±3% | 0.1m/s |
| Wind direction | 0~360° | ±3° | 1° |
| Temperature | -50℃~60℃ | ±0.2℃ | 0.1℃ |
| Humidity | 0~100% RH | ±2%RH | 0.1%RH |
| Air pressure | 300~1200hPa | ±0.3hPa | 0.1hPa |
| Rainfall | 0.01~4mm | - | 0.5mm |



|