Sign In | Join Free | My insurersguide.com |
|
Categories | Lab Test Chamber |
---|---|
Brand Name: | MENTEK or OEM |
Model Number: | MUVS-5002000 |
Place of Origin: | China |
MOQ: | 1 Unit |
Price: | 3000USD |
Supply Ability: | 30 sets per month |
Delivery Time: | 10-15 working days after order confirmed |
Packaging Details: | strong plywood box |
Material: | SUS 304 Stainless Steel |
UV Lamp Qty: | 16 PCS |
Conveyor width: | 500mm |
Power supply: | AC220V 3Φ 2.35KW 50Hz |
Maximum load capacity: | 2.35 KW |
Total equipment length:: | 2000mm |
Item | Index | Test Method | |||||||||||||||||||||||||||||||||||||||||||||||||||||
Total number of colonies, CFU/g ≦ | 1000 | GB 4789.2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||
Coliform bacteria, MPN/100g ≦ | 40 | GB 4789.3 | |||||||||||||||||||||||||||||||||||||||||||||||||||||
Pathogenic bacteria (Salmonella, Shigella, Staphylococcus aureus) | Shall not be detectable | GB 4789.4 GB 4789.5 GB 4789.10 | |||||||||||||||||||||||||||||||||||||||||||||||||||||
Serilizing parameter | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Advantages of UV disinfection technology
The disinfection effect of ultraviolet C disinfection technology on
bacterial viruses and other pathogens has been recognized
worldwide, and it has unparalleled bactericidal efficiency. The
germicidal effect of ultraviolet rays on bacteria and viruses is
generally within one second. For traditional chlorine and ozone
methods, it takes 20 to 50 minutes to achieve the sterilization
effect of ultraviolet rays. It has a broad spectrum of efficient
sterilization, no secondary pollution, safe and reasonable design,
safe and reliable operation. Simple maintenance and low cost. This
equipment occupies a small area and has no noise. It can
continuously sterilize in large quantities, and has a wide range of
applications.
Application
Specification (Customized design is available according to customer
requirements)
1. Total equipment length: 2000mm
2. Working area length: 1000mm
3. Feeding operation area: 500mm Discharging operation area: 500mm
4. Height of entrance and exit: 200mm
5. Conveyor width: 500mm
6. Conveyor belt from the ground: 750 ± 20mm
7. A total of 16 lamps are installed in the sterilizer, each power
20W
Structure
1. Work area tunnel body: high-quality SUS304 stainless steel
2. Working area tunnel cavity: mirror stainless steel Model: # 304
3. Body support frame: one set of Square Steel Model: 2 ″
4. Air transport system: a set of forced air transport exhaust fans
(extracting harmful gas) Model: 6 inches
5. Thermal insulation material: Vacuum aluminum silicate + silk
cotton double layer Model: 60K
6. Conveyor belt: Teflon mesh belt 1. Main switch: 20A
7. Transport motor: 800W (inverter speed regulation)
8. Speed governor: 500W (electronic stepless inverter speed
regulation digital display speed operation)
9. Exhaust fan: CY-125
10. Ammeter: 50A set
11.Voltage: 220V
12. Working voltage: 200V--220V (± 5) Three-wire system 50Hz
Usage Instructions
Effective light moment of ultraviolet light source: 150mm
Tube length 460mm
16 UV germicidal lamp tubes * 20W UV lamps are located in the inner
cavity longitudinally,
and there are installed on the top, bottom, left and right
The wavelength is 253.7nm, and the radiation intensity at a
distance of 1 meter is more than 160 microwatts per square
centimeter.
Power supply equipment and precautions
(1) Power supply: AC220V 3Φ 2.35KW 50Hz
※ Allowable fluctuation range of voltage: ± 5% of rated value
※ (but the operating range is ± 10%)
(2) Maximum load capacity: 2.35 KW
(3) Maximum current: 50A
(4) When placing the box, pay attention to the distance from the
wall should be greater than 100 mm.
Maintenance and maintenance of UV sterilizer:
1 Regular inspection to ensure the normal operation of the UV lamp.
2. After continuous use for 8000 hours or one year, the UV lamp
should be replaced. When replacing a new lamp, first unplug the
lamp power socket and take out the ultraviolet lamp. Be careful not
to touch the quartz glass of the new lamp with your fingers, as the
stain will affect the intensity of the light. At the same time,
carefully put the lamp into the interior of the sterilizer.
![]() |