| Brand Name: | YUYANG | 
| Model Number: | YY714 | 
| Certification: | DIN 50055, ISO 9705, EN 13823, IEC 60332 Part 3, EN ISO 9239-1 | 
| Place of Origin: | China | 
| MOQ: | 1 set | 
| Price: | Negotiation | 
| Payment Terms: | T/T, L/C, Western Union | 
| Supply Ability: | 5 sets per quarter | 
| Delivery Time: | 15 work days | 
| Packaging Details: | Plywood Box | 
| Product Name: | Smoke Density Tester | 
| Usage: | White Light Smoke Test | 
| Material: | Stainless Steel | 
| Power: | 220V 50HZ 16A | 
| Weight: | 20kg | 
| Dimension: | 85(W)*55(D) *45(H) | 
| Company Info. | 
| DONGGUAN YUYANG INSTRUMENT CO., LTD | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
White Light Smoke Measurement System Used for ISO 9705, EN 13823, EN ISO 9239-1
Introduction:
‘Smoke Density Photometric System’ (DIN 50055) is designed to be used in conjunction with equipment that measures smoke from burning materials. The unit can be fitted to several instruments such as the Room Corner Test, (ISO 9705), Single Burning Item (SBI), (EN 13823), Heat Release Apparatus for IEC 60332 Part 3 (as developed in the FIPEC project), Steiner Tunnel or Flooring Radiant Panel (EN ISO 9239-1) etc.
The apparatus consists of:
1. Light Source
2. Light Measuring System
3. Control Unit
Standards:
DIN 50055, ISO 9705, EN 13823, IEC 60332 Part 3, EN ISO 9239-1
Detailed Parameter:
The Light Source is a gas filled tungsten filament lamp. Power for the lamp is provided by a regulated power supply housed in the Control Unit.
1. The Light-Measuring Device consists of: -
2. Achromatic system of lenses
3. Silicon photo-electric cell
4. High gain low noise amplifier
These components are housed in an assembly with a collimating lens.
The signal from the Light-Measuring Device is taken to the Control Unit, which is capable of continuously measuring relative light intensity against time as percentage transmission over the ranges to be studied. The system has a linear response with respect to transmittance and an accuracy of better than ±1.5% of the maximum reading. The Control Unit also regulates the damping of the amplifier so that the response times required to achieve 95% accuracy (T95) correspond to the specifications given in the standard.
An analogue output on the control unit of 0–1V = 100% transmission is available to be taken to a data acquisition unit. A Windows based software package is also available to enable simple data acquisition, analysis and storage via a data logger. All parameters are displayed. The versatile data logger may be used in other applications and is supplied with software that allows the data stored in the logger to be downloaded to a PC for further analysis.
|   | 
 EN 50268 Stainless Steel Cable Smoke Density Tester For Fiber Optic Cable
                                                                                    
                        
                        
                        
                                                            EN 50268 Stainless Steel Cable Smoke Density Tester For Fiber Optic Cable
                                                    
                        
                     210kg Smoke Density Chamber , Imo / Rail Smoke Density Test Apparatus
                                                                                    
                        
                        
                        
                                                            210kg Smoke Density Chamber , Imo / Rail Smoke Density Test Apparatus
                                                    
                        
                     White Smoke Density Tester 35kg For Plastics Burning / Decomposition
                                                                                    
                        
                        
                        
                                                            White Smoke Density Tester 35kg For Plastics Burning / Decomposition
                                                    
                        
                     Integrated Design Smoke Density Tester / Instrument For Solid Materials
                                                                                    
                        
                        
                        
                                                            Integrated Design Smoke Density Tester / Instrument For Solid Materials
                                                    
                        
                     Laboratory Smoke Density Tester For Industrial Material Noxious Gas Analysis
                                                                                    
                        
                        
                        
                                                            Laboratory Smoke Density Tester For Industrial Material Noxious Gas Analysis
                                                    
                        
                     Stainless Steel Cable Smoke Density Apparatus , Lab Testing Machine IEC61034 BS6853
                                                                                    
                        
                        
                        
                                                            Stainless Steel Cable Smoke Density Apparatus , Lab Testing Machine IEC61034 BS6853
                                                    
                        
                     Mass Loss Gas Analysis Ignition Timing Tester / Combustion Toxicity Test Apparatus
                                                                                    
                        
                        
                        
                                                            Mass Loss Gas Analysis Ignition Timing Tester / Combustion Toxicity Test Apparatus
                                                    
                        
                     Material Smoke Density Tester For Noxious Gas Analysis DIN 53436 JIS 1321
                                                                                    
                        
                        
                        
                                                            Material Smoke Density Tester For Noxious Gas Analysis DIN 53436 JIS 1321
                                                    
                        
                     Wire / Cable Smoke Density Tester For Needle Flame Test IEC61034
                                                                                    
                        
                        
                        
                                                            Wire / Cable Smoke Density Tester For Needle Flame Test IEC61034
                                                    
                        
                     High Accuracy Smoke Density Test Apparatus For Building Material ASTM D2843
                                                                                    
                        
                        
                        
                                                            High Accuracy Smoke Density Test Apparatus For Building Material ASTM D2843