| Rated Voltage: | AC380V | 
| Dielectric strength: | >2kVAC 1min | 
| Phase loss tripping time: | 1s | 
| Measurement error: | ≤1% with ajustable volatage range | 
| Dimensions (H x W x D): | 80X43X54mm | 
Reliance on the disappearance of a current in a phase conductor of a polyphase circuit to disconnect a protected device or rely on the loss of one or more phases of a polyphase system to prevent a protection device that applies power to a protected device, also known as a protection device. Phase protector, phase loss protector.
This type of detection voltage can also be called three-phase power supply monitor, phase sequence protector, over voltage protection device, etc.) Mainly used for AC 50/60Hz, rated voltage below 460V, industrial three-phase 220V, 380V, 440V , 460V and other voltage levels of various fault detection, the three-phase input power supply voltage is too high, voltage is too low, lack of phase, phase failure, reverse phase (phase sequence), three-phase voltage imbalance, etc. to provide protection relay products Widely used in distribution boxes, central air-conditioning units, electric control boxes, power distribution cabinets, cranes, etc., such as central air-conditioning compressor protection, power monitoring of various elevators, pumps, oil pumps against phase loss, reverse phase protection, etc. An indispensable protective product that maintains the normal working voltage of the equipment during operation.
-- Built-in LCD and keypad afford a precise,digital setting-- Three-phase monitoring of phase sequence, phase loss, over- and undervoltage and phase unbalance-- Adjustable over- and undervoltage, phase unbalance threshold-- Independent adjustable delay time for overvoltage, undervoltage, phase unbalance-- Powered by the measuring circuit-- 1 NO & 1NC contacts-- Faulure recording
♦ Protective Functions
-- Phase sequence
-- Phase loss
-- Phase unbalance
-- Overvoltage
-- Undervoltage
Applications Pumps / Fans Blowers / Motors / Compressors ,have the CE CCC Certain ,make sure every product Quality ,Meet industry standards
♦ Technical data
| Type | JVR1000 | 
| Measuring circuit | L1,L2,L3 | 
| Rated voltage | 380VAC ,50Hz | 
| Monitoring functions | phase sequence, phase loss, overvolatege, undervoltage,phase unbalance | 
| Overvoltage setting range | 390-490V adjustable | 
| Undervoltage setting range | 300-470V adjustable | 
| Hysteresis | 10V | 
| Delay time for overvoltage and undervoltage | 0.1-25s adjustable | 
| Phase unbalance setting range | 5%-29% adjustable | 
| Delay time for phase unbalance | 1-25s adjustable | 
| Delay time for phase loss | 1s | 
| Delay time for phase sequence | instant | 
| Indicators | LCD indicating voltage,current,operation status | 
| Output contacts | 1 NO,1NC | 
| Contact capacity | 6A ,250VAC | 
| Dimensions (H x W x D) | 80×40×54mm | 
| Mounting | DIN rail | 

|   | 
 Pumps Three Phase Voltage Monitoring Relay , JVM-A Phase Detection Relay 460VAC
                                                                                    
                        
                        
                        
                                                            Pumps Three Phase Voltage Monitoring Relay , JVM-A Phase Detection Relay 460VAC
                                                    
                        
                     Phase sequence Three Phase Voltage Monitoring Relay Miniature voltage relay
                                                                                    
                        
                        
                        
                                                            Phase sequence Three Phase Voltage Monitoring Relay Miniature voltage relay
                                                    
                        
                     Digital Three Phase Voltage Monitoring Relay Over voltage protector AC380V 6A
                                                                                    
                        
                        
                        
                                                            Digital Three Phase Voltage Monitoring Relay Over voltage protector AC380V 6A
                                                    
                        
                     Elevator part Three Phase Voltage Monitoring Relay phase failure protective deivce 380VAC Din rail
                                                                                    
                        
                        
                        
                                                            Elevator part Three Phase Voltage Monitoring Relay phase failure protective deivce 380VAC Din rail
                                                    
                        
                     Water Pumps Three Phase Voltage Monitoring Relay 380V protector 1CO  6A contact capacity
                                                                                    
                        
                        
                        
                                                            Water Pumps Three Phase Voltage Monitoring Relay 380V protector 1CO  6A contact capacity
                                                    
                        
                     Compressors Used Three Phase Voltage Monitoring Relay 1-25s time delay protector
                                                                                    
                        
                        
                        
                                                            Compressors Used Three Phase Voltage Monitoring Relay 1-25s time delay protector
                                                    
                        
                     6A Three Phase Voltage Monitoring Relay for electric motors voltage control relay
                                                                                    
                        
                        
                        
                                                            6A Three Phase Voltage Monitoring Relay for electric motors voltage control relay
                                                    
                        
                     Phase failure detection Three Phase Voltage Monitoring Relay 200V-500V , 50/60Hz
                                                                                    
                        
                        
                        
                                                            Phase failure detection Three Phase Voltage Monitoring Relay 200V-500V , 50/60Hz
                                                    
                        
                     Phase reversal protector Three Phase Voltage Monitoring Relay 2 CO , 6A
                                                                                    
                        
                        
                        
                                                            Phase reversal protector Three Phase Voltage Monitoring Relay 2 CO , 6A
                                                    
                        
                     Reliable  Three Phase Voltage Monitoring Relay of three-phase mains phase failure DIN rail mount
                                                                                    
                        
                        
                        
                                                            Reliable  Three Phase Voltage Monitoring Relay of three-phase mains phase failure DIN rail mount