| Sign In | Join Free | My insurersguide.com | 
 | 
| Categories | Inductive Load Bank | 
|---|---|
| Brand Name: | KAIXIANG | 
| Model Number: | AC440V(690V)-6050kVA-RL | 
| Certification: | ISO9001 | 
| Place of Origin: | CHINA | 
| MOQ: | 1 set | 
| Price: | negotiable | 
| Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram | 
| Supply Ability: | 15 Sets per Month | 
| Delivery Time: | Within 30 working days | 
| Packaging Details: | Wooden Case for Load bank | 
| Atmospheric Pressure: | 86~106kPa | 
| Casing Color: | Grey(RAL7035) | 
| Max Rated power: | Apparent Power: 6050kVA Resistive Power: 4840kW Reactive Power: 3630kvar | 
| Data processing software: | Kaixiang(self-developed) | 
| weight: | 25000kg | 
| Ambient Temperature: | -10℃~+50℃ | 
Ocean Engineering 440V(690V) 6050kVA Inductive Load Bank For
Generator Testing
Product description
Load Banks are used with Engine Generators, Battery Systems, UPS Systems, Inverters, Ground Power Units, Auxiliary Power Units, Aircraft Power Generators, Wind Generators, and Hydro Generators.
Technical Parameter
| Rating Voltage/Frequency | angle form 440VAC/60Hz, Star class 690v 50hz | 
| Max Rated power | Apparent Power: 6050kVA Resistive Power: 4840kW Reactive Power: 3630kvar | 
| Load Resolution | Resistive Load: 1.2.2.5.10.10.20.20.50.100.200.200.200.200.200.200.200.200.200.200.200kw Reactive load:1.2.2.5.10.10.20.20.50.100.200.200.200.200.200.200.200.200kvar | 
| PF(Power Factor) | 0.8 | 
| Load Tolerance (each step) | ±5% | 
| Load Tolerance(overall) | ±3% | 
| Display Precision | 0.5 class | 
| Control Power | 380VAC/50Hz, | 
| Wire Connection | Load power supply input——Copper bar (star coupling) Control power supply input——Connector-bar | 
| Communication Interface | RS485, | 
| Casing Dimensions and Cooling | about 9150*2350*2896mm (length*width*height) Forced air cooling,Horizontal inlet air,Vertical cooling | 
| Weight | About 25000kgs/set | 
Product Advantage
1. Communication type: through RS232, RS485 or USB interface.
2. Load mode: manual load or automatic load.
3. Manual load: input power and power factor.
4. Automatic load: User can set several periods of power and time, and in turn of 0%→25%→50%→75%→100%, etc preset order to make automatic load testing.
Application
Generators installed in the field must be periodically tested and exercised to ensure that it will operate as intended when a power outage actually occurs. Service groups use load banks to apply a load that mimics the load of the facility the generator is protecting. Any problems with the generator can then be identified and rectified in a non-critical environment.

|   | 
 High Frequency 300KVA Load Bank Testing Equipment 3 Phase 4 Wire
                                                                                    
                        
                        
                        
                                                            High Frequency 300KVA Load Bank Testing Equipment 3 Phase 4 Wire
                                                    
                        
                     LED Display 300KVA Inductive Load Bank For Diesel Gnerator Testing
                                                                                    
                        
                        
                        
                                                            LED Display 300KVA Inductive Load Bank For Diesel Gnerator Testing
                                                    
                        
                     Ocean Engineering Inductive Load Bank , Blue Variable Resistive Load Bank
                                                                                    
                        
                        
                        
                                                            Ocean Engineering Inductive Load Bank , Blue Variable Resistive Load Bank
                                                    
                        
                     Apparent Power Inductive Load Bank High Power Density For Testing
                                                                                    
                        
                        
                        
                                                            Apparent Power Inductive Load Bank High Power Density For Testing
                                                    
                        
                     440 V Inductive Load Bank Lightweight With Intelligent Operator Controls
                                                                                    
                        
                        
                        
                                                            440 V Inductive Load Bank Lightweight With Intelligent Operator Controls
                                                    
                        
                     Full Automatic Inductive Or Resistive Load Bank 3500 Kg With Reasonable Layout
                                                                                    
                        
                        
                        
                                                            Full Automatic Inductive Or Resistive Load Bank 3500 Kg With Reasonable Layout
                                                    
                        
                     Display Test Outcome Inductive Load Bank With 86 ~106 KPa Atmospheric Pressure
                                                                                    
                        
                        
                        
                                                            Display Test Outcome Inductive Load Bank With 86 ~106 KPa Atmospheric Pressure
                                                    
                        
                     0.5 Class Display Precision Inductive Load Bank , Diesel Load Bank Cabinet
                                                                                    
                        
                        
                        
                                                            0.5 Class Display Precision Inductive Load Bank , Diesel Load Bank Cabinet
                                                    
                        
                     Reactive Power Inductive Load Bank 50 HZ Grey For Drilling Facilities
                                                                                    
                        
                        
                        
                                                            Reactive Power Inductive Load Bank 50 HZ Grey For Drilling Facilities
                                                    
                        
                     Full Automatic 1000 KVA AC Load Bank Testing Equipment For Genset Testing
                                                                                    
                        
                        
                        
                                                            Full Automatic 1000 KVA AC Load Bank Testing Equipment For Genset Testing