| Sign In | Join Free | My insurersguide.com | 
 | 
| Categories | Single Phase Energy Meter Test Bench | 
|---|---|
| Brand Name: | SHENGDI TECHNOLOGY | 
| Model Number: | HS6103F | 
| Certification: | GS,CNAS | 
| Place of Origin: | ZHEJIANG,CHINA | 
| MOQ: | 1 SET | 
| Price: | USD$1~100000/SET | 
| Payment Terms: | TT,LC | 
| Supply Ability: | 500 sets/Years | 
| Delivery Time: | 35~45days | 
| Packaging Details: | WOODEN CASE | 
| Accuracy: | 0.05%,0.1% | 
| Current Output: | 1mA~120A | 
| Positions: | 48 meters | 
| Communication: | RS485 | 
| Company Info. | 
| Zhejiang Shengdi Technology Inc. | 
| View Contact Details | 
| Product List | 
HS-6103F SINGLE PHASE ENERGY METER TEST BENCH
AUTOMATIC CHANGE TO CALIBRATE/TEST LINE AND NEUTRAL
(48 POSITIONS)
This specification for single phase dual loop energy meter test bench.
Voltage Source:
1. Output Voltage Range: 0- 275/300V
2. Output Max Power: 800VA
3. Resolution: 0.01%
4. Stability: Better than 0.05% / 3 Min(Time base 5S)
5. Distortion factor: < 0.5% at linear load;
6. Frequency range: 45Hz~65Hz;
7. Power efficiency: more than 85%;
8. Ambient temperature:10℃~50℃
9. Electronic overload and short-circuit protection.
Current Source:
1. Output current: range: 1mA~100A;+/-20%
2. Output maximum power: 2000VA
3. Resolution: 0.01%;
4. Stability:better than 0.05%/3 min(time base 5S);
5. Distortion factor: < 0.5% at linear load;
6. Frequency range: 45Hz~65Hz;
7. Power efficiency: greater than 85%;
8. Ambient temperature:10℃~50℃
9. Electronic overload protection and security for open current circuit.
Reference Meter:
HS-5100 Single Phase Reference Meter Accuracy class :0.05%

Accessories:
1. Phase Angle: 0°~360° , resolution of phase angle setting: 0.1°;
2. Output frequency range: 45Hz~65Hz; resolution: 0.01Hz
3. Output stability of power: <0.05% (180S)
4.. Input power: 220/240V +/-15%, 50/60Hz;
5. RS485 Communication Capacity.Universal Serial Bus
6. Current Connect Type: 1-4,3-2 (Dual Loop)
Dimensions:
| Type of bench | Meters | Number | Number of row | Size | 
| Integration | 6 12 24 48 | 1 1 1 2 | Single Double Double Double | 1600×750×1100 mm 1600×750×1920 mm 2200×750×1920 mm 2000×750×1920 mm | 
| Fission | 12 16 24 48 | 1 1 1 2 | Single Double Double Double | 1600×700×1920 mm 2200×700×1920 mm 2200×700×1920 mm 2000×700×1920 mm | 
| Cabinet: 600×800×1920 mm | ||||




|   | 
 Single Phase Meter Test Bench,48 calibrated energy meter, 0.001Amps~120Amps,30~300Volts
                                                                                    
                        
                        
                        
                                                            Single Phase Meter Test Bench,48 calibrated energy meter, 0.001Amps~120Amps,30~300Volts
                                                    
                        
                     12-16 Positions Single Phase Prepaid Digital KWH Meter Test Bench 1mA~120A Current,0.05% Accuracy Class
                                                                                    
                        
                        
                        
                                                            12-16 Positions Single Phase Prepaid Digital KWH Meter Test Bench 1mA~120A Current,0.05% Accuracy Class
                                                    
                        
                     12 Pcs Single Phase Prepaid Digital KWH Meter Test Bench 0.5mA~120A Current Range,0.05% Accuracy Class
                                                                                    
                        
                        
                        
                                                            12 Pcs Single Phase Prepaid Digital KWH Meter Test Bench 0.5mA~120A Current Range,0.05% Accuracy Class
                                                    
                        
                     12 position ANSI 4 IEC single phase test bench accuracy class 0.05% ANSI SOCKET Meter 0~100A current
                                                                                    
                        
                        
                        
                                                            12 position ANSI 4 IEC single phase test bench accuracy class 0.05% ANSI SOCKET Meter 0~100A current
                                                    
                        
                     48 position single phase energy meter test bench,0.1% Accuracy class.1-4,3-2 double CIRCUIT current meter for INDIA
                                                                                    
                        
                        
                        
                                                            48 position single phase energy meter test bench,0.1% Accuracy class.1-4,3-2 double CIRCUIT current meter for INDIA
                                                    
                        
                     Single phase energy meters test bench (10/20 meters at a time) 0.05%/0.1% Accuracy class Max.120A current
                                                                                    
                        
                        
                        
                                                            Single phase energy meters test bench (10/20 meters at a time) 0.05%/0.1% Accuracy class Max.120A current
                                                    
                        
                     Single phase test bench for digital energy meter 1~48 Positions,0.05% Accuracy class,0~100A current range
                                                                                    
                        
                        
                        
                                                            Single phase test bench for digital energy meter 1~48 Positions,0.05% Accuracy class,0~100A current range
                                                    
                        
                     HS-6103F Single-phase Digital kWh Energy Meter Test Bench 2 circuit current test 48 positions
                                                                                    
                        
                        
                        
                                                            HS-6103F Single-phase Digital kWh Energy Meter Test Bench 2 circuit current test 48 positions
                                                    
                        
                     Single Phase Electronic DIN Rail Active Energy Test Bench 30 Positions 0.05% Accuracy Class 0~100A current range
                                                                                    
                        
                        
                        
                                                            Single Phase Electronic DIN Rail Active Energy Test Bench 30 Positions 0.05% Accuracy Class 0~100A current range
                                                    
                        
                     HS-6103 Single Phase DIN Rail Electricity Meter Test Bench 30 Positions 0.05% Accuracy Class 0~100A current range
                                                                                    
                        
                        
                        
                                                            HS-6103 Single Phase DIN Rail Electricity Meter Test Bench 30 Positions 0.05% Accuracy Class 0~100A current range