| Sign In | Join Free | My insurersguide.com | 
              
  | 
      
| Categories | Switching Power Supply | 
|---|---|
| Place of Origin: | Shenzhen, Guangdong, China | 
| Brand Name: | WORLD SHARE | 
| Model Number: | WST-PS-XXXYYYY | 
| Output Type: | Single | 
| Output Voltage: | 5V 12V 24V etc. | 
| Output Current: | 0-30A DC | 
| MOQ: | 1 | 
| Packaging Details: | 1pc in a box, 50pcs in a standard carton, welcome to customized. | 
| Delivery Time: | 1-10 days | 
| Payment Terms: | Western Union, T/T, etc. | 
| Supply Ability: | 5000pcs/day | 
| Output Power: | 0-360W | 
| Input Voltage: | 90-264V AC | 
110V 220V AC to 5V 12V 24V DC Output Variable Voltage Switch Mode Power Supplies
Application: Industrial, security monitoring, machine, equipment, LED billboard, medical treatment, electrical, communications, etc.
Feature:
1. Full range of input (Selectable by switch)
2. Over current, over voltage and short circuit protection
3. 100% full load test
4. Low price and reliable quality
5. Two years’ warranty
Technical specification
Input Voltage: 85-264V AC, 47-63Hz; 120-370V DC
Impact Current: Cold start current
DC Voltage Adjustable Scope: 10% of the rated output voltage
Overload Protection: 115% ~ 150% of current, automatic recovery
Over Voltage Protection: 115%-135% of output voltage
Start, Rising and Hold-up Time: 300ms, 50ms, 80ms
Withstanding Voltage: 1.5KV AC between input and output, 1.5KV AC between input and shell, 0.5KV AC between output and shell: all last for one minute.
Working Temperature: -10-+ 60°C
Relative Humidity: 20-90% RH
Safety Standards: Complying with CE standard
EMC Standards: Complying with CE standard
Technical Specification  | ||||
Max. Output Wattage  | 36-60W  | |||
Input  | Voltage  | 90-260V AC  | ||
Frequency  | 50-60Hz  | |||
Current (Full load)  | 2.0A Max. (115V AC), 1.2A Max. (230V AC)  | |||
Inrush Current  | Cold Start 40A/230V AC  | |||
Leakage Current  | <2mA (240V AC)  | |||
Output  | Voltage  | 5V DC  | 12V DC  | 24V DC  | 
Voltage Accuracy  | ±3%  | ±2.5%  | ±1.25%  | |
Max. Current  | 8  | 5  | 3  | |
Line Regulation  | ±0.5%  | ±0.5%  | ±0.5%  | |
Load Regulation  | ±1%  | ±1%  | ±1%  | |
Min. Load  | 0%  | 0%  | 0%  | |
Typical Efficiency  | 83%  | 84%  | 88%  | |
Adjustable Range of Voltage  | 4.5-6.5V DC  | 9-15V DC  | 22-27V DC  | |
Max. Ripple & Noise  | 150mV  | 150mV  | 150mV  | |
Hold-up Time  | 20ms Min.  | |||
Switching Frequency  | 60KHz  | |||
Protection  | Over Load  | 105-150% of Rated Output Power Protection Type: Auto Recovery  | ||
Short Circuit  | Protection Type: Auto Recovery  | |||
Electric Strength  | Input-Output  | 1500V AC  | ||
Input-FG  | 1500V AC  | |||
Output-FG  | 1500V AC  | |||
Isolation Resistance  | Input-Output, Input-FG, Output-FG: 100Mohms/500V DC  | |||
Environment  | Operating Temperature  | -10-+50°C (Refer to The Point 4 Output Load Deration Curve)  | ||
Storage Temperature  | -25-+85°C  | |||
Temperature Coefficient  | ±0.03%°C(0°C<t<50°C)  | |||
Humidity  | 95%RH  | |||
MTBF  | >50000h@25°C(MIL-HDBK-217F)  | |||
Vibration  | 10-500Hz, 2G 10Min./Cycle, 60Min. Along X, Y, Z Axes  | |||
Feature  | Dimension(L*W*H)  | |||
Weight  | ||||
Cooling Method  | Naturally Air-cooled  | |||
Safety & EMC  | Safety Standards  | UL60950 EN60950  | ||
EMI  | EN55011 Class B EN55022 Class B  | |||
EMS Immunity  | EN55024 EN61000-6-2  | |||
Harmonic Current  | EN61000-3-2  | |||
                                 
                             |