Categories | Primary Current Injection Test Set |
---|---|
Brand Name: | Huaying |
Model Number: | Huaying Series |
Certification: | ISO |
Place of Origin: | Wuhan Hubei China |
MOQ: | 1 Set |
Price: | negotiable |
Payment Terms: | T/T L/C |
Supply Ability: | 200 sets per month |
Delivery Time: | 7 Working Days |
Packaging Details: | Wooden Case |
Power supply: | AC220V or AC 400V |
Maximum output current: | 500A~25000A |
Function: | For current transformer and circuit breaker testing |
Current distortion: | <5% |
Warranty: | 1 year and lifelong maintance |
Duty Cycle: | Customized |
Substation Maintenance Primary Current Injection Test Set AC220V Or AC 400V
1. Product Name:
Primary Current Injection Test System SLQ
2. Equipment Description:
SLQ primary injection test set is a high current generator instrument. It is applied in current transformer test , circuit breaker test and so on. Adjustable output current, smooth in current rise, large scope of load variation, easy and safe operation.
3.Technical Parameters:
1 Power supply: AC220V or AC 400V, 45Hz~65Hz. The power supply
voltage is depends on the power output capacity. Detail information
is as table 1.
2 Maximum output current: 500A~25000A. Detail information is as
table 1. 3 Impendence voltage: 8%
4 Idle current: 6%
5 Current distortion <5%
6 Current is measured from the secondary of current transformer
which is installed in the internal of the current booster. The
display mode is customized according to the requirement of customer
from the follow list:
1> Analog Current Meter, accuracy class 0.5
2> 4 and 1/2 digitals current meter, accuracy class 0.5
7 Timer indication of test running is an optional configuration.
The timer could be customized according to the requirement of
customer from the follow list:
1) 4 digital timer from 0~9999s / 0~999.9s /0~99.99s, accuracy
0.5%RDG+5D
2) 5 digital timer from 0~99999s / 0~9999.9s /0~999.99s, accuracy
0.2%RDG+2D
3) 6 digital timer from 0~999999s / 0~99999.9s /0~9999.99s,
accuracy 0.1%RDG+1D
Addition:
Type | Capacity (kva) | Power supply | Output | Impedance voltage % | Idle current % | mode | ||
I (A) | V (V) | I (A) | V (V) | |||||
SLQ-5/500 | 3 | 13.6 | 220 | 500 | 5 | >8 | >6 | single |
SLQ -5/1000 | 5 | 22.7 | 220 | 1000 | 5 | >8 | >6 | single |
SLQ -10/2000 | 10 | 46 | 220 | 2000 | 5 | >8 | >6 | Separated |
SLQ -12/4000 | 12 | 30 | 400 | 2000/4000 | 6/3 | >8 | >6 | Separated |
SLQ -15/5000 | 15 | 37.5 | 400 | 2500/5000 | 6/3 | >8 | >6 | Separated |
SLQ -150/25kA | 150 | 375 | 400 | 25000 | 6 | >8 | >6 | Separated |
Environment temperature: 0~50°C
Humidity: ≤85%RH