Categories Micro Temperature Sensor
Brand Name: Aolittel
Model Number: ISB-TS45H
MOQ: 1000 Pieces
Price: Negotiable
Payment Terms: T/T, Western Union
Supply Ability: 10,000,000 Pieces Per Month
Delivery Time: 2-4 Weeks
Packaging Details: Bulk
Product Name: IR Infrared Thermopile Temperature Sensor
Product Category: Infrared Detectors
Type: Thermopile
Package / Case: TO-46
Mounting Style: Through Hole
Minimum Operating Temperature: - 30 C
Maximum Operating Temperature: + 85 C
Height: 2.9mm
Product: Thermal Infrared Detectors
Response Time: ≤ 13 msec
Noise Equivalent Power - NEP: 0.23 nW/Hz1/2
Subcategory: Subcategory
Unit Weight: 85 gram
NTC Resistance: 100KOhm±3%
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    TO-46 Package IR Infrared Thermopile Temperature Sensor 100K 3950 ISB-TS45H For Contactless Temperature Measurement


    TO-46 Package IR Infrared Thermopile Temperature Sensor 100K 3950 ISB-TS45H For Contactless Temperature Measurement


    Performances


    ISB-TS45H
    ParameterMin.Typ.Max.UnitConditons
    Chip size1.1×1.1mm2
    Sensitve area0.35×0.35mm2
    Detection angle90°
    Thermopile resistance8098115Temp=25℃
    Noise voltage38nV/Hz1/2Temp=25℃
    NEP0.23nW/Hz1/2Blackbody=500K,1Hz@25℃
    Voltage Response20.11Vmm2/wBlackbody=500K,1Hz@25℃
    Responsivity134164194V/wBlackbody=500K,1Hz@25℃
    Temp.coefcient of resistance0.06%/℃Temp=25℃~75℃
    Time constant≤ 13ms
    Specifc detectvity1.51 E08cmHz1/2/wBlackbody=500K,1Hz@25℃
    NTC Resistance100±3%25℃
    NTC β3950±1%K25/50℃

    ______________________________________________________________________________Epoxy Coated Photocell 11mm Diameter Photoresistor Light Sensor GM11528 With Light Resistance 10-20 KOhm Download________


    Dimension


    unit:mm



    Environmental requirements


    Operating Temperature:-30℃~ +85℃

    Storage Temperature :-30℃~ +100℃

    Test conditions: 25℃ ambient temperature, the measured object temperature and the typical output voltage of the reactor corresponding relationship.

    * Note: This parameter is tested under TO46 package plus LWP5.0 filter condition.


    TempV outTempV outTempV outTempV outTempV out
    (℃ )(mv)(℃ )(mv)(℃ )(mv)(℃ )(mv)(℃ )(mv)
    -20-3.04610-1.196401.334704.4771008.508
    -19-2.98311-1.131411.426714.6061018.667
    -18-2.92912-1.051421.526724.731028.839
    -17-2.87913-0.973431.624734.8451039.001
    -16-2.82914-0.888441.725744.9621049.172
    -15-2.77715-0.806451.81755.0811059.335
    -14-2.72416-0.723461.892765.2051069.499
    -13-2.67317-0.646471.995775.3211079.664
    -12-2.61918-0.572482.094785.4551089.83
    -11-2.56919-0.494492.199795.5871099.991
    -10-2.51420-0.417502.306805.72411010.15
    -9-2.46121-0.33512.42815.84811110.32
    -8-2.39922-0.248522.53825.98111210.48
    -7-2.33823-0.164532.635836.11611310.64
    -6-2.27524-0.083542.753846.25111410.81
    -5-2.214250552.865856.37611510.98
    -4-2.144260.086562.969866.51411611.15
    -3-2.084270.174573.08876.64111711.33
    -2-2.022280.258583.185886.76711811.5
    -1-1.964290.346593.299896.90711911.66
    0-1.899300.446603.401907.04312011.84
    1-1.829310.544613.508917.19
    2-1.754320.623623.608927.33
    3-1.689330.709633.715937.468
    4-1.629340.798643.808947.604
    5-1.155350.892653.91957.751
    6-1.479360.974664.019967.9
    7-1.416371.062674.123978.051
    8-1.349381.149684.239988.191
    9-1.275391.246694.354998.344

    Spectral curve


    Transmission rate % Wavelength(nm)


    Application


    Climate control

    Medical : Ear thermometer,Forehead thermometer

    Non-contact temperature measurement

    Industrial continuous temperature control,Industrial pyrometers


    Description


    Aolittel ’s thermopile sensors Temperature sensor can measure temperature by detecting the infrared energy of an object outside a certain distance. The temperature is higher, infrared energy produced would be more.

    Thermopile sensing elements consist of small thermocouples on silicon chips that absorb energy and produce output signals.


    These benefits include better performance and reliability as well as ease-of-use and overall simplicity when incorporating movement into a design. IR thermopiles also allow ambient temperature readings to be factored-in, thus providing greater accuracy and temperature control.


    Thermopiles are mainly used for contactless temperature measurement in many applications. Their function is to transfer the heat radiation emitted from the objects into a voltage output.The product consists of infrared filters, thermistors and other components, after TO-46 Metal encapsulated, with high reliability and high sensitivity.


    Features


    Thermopile IR-Sensor

    For Contactless Temperature Measurement

    Single Element

    High Signal

    Accurate Reference Sensor

    TO-46 Package

    High Sensitivity

    NTC Thermistor Compensation

    Fast Response Time

    5μm Longpass Flat Filter


    Precautions


    1. Design restrictions


    The sensor is designed for indoor use.

    When used in outdoor applications, be sure to use a suitable supplemental optical filter and moisture-proof structure.

    To prevent secondary failures due to operational failures or malfunctions, fail-safe features can be added in advance.


    2.Use restrictions


    To prevent sensor failure, operational malfunction or any other malfunction, do not use this sensor under or under similar conditions.

    A. Severe changes in ambient temperature.

    B. Strong vibration or vibration.

    C. When passing through a place with a barrier material (glass, fog, etc.), infrared rays cannot pass through the detection area.

    D. In liquids, corrosive gases and seawater.

    E. Continuous use in a high-humidity atmosphere.

    F. Static electric field or strong electromagnetic radiation.

    G. Corrosive gas or sea breeze.

    H. Dirty and dusty environment that may contaminate the optical window.


    3.Welding restrictions


    A. Soldering with soldering iron. The soldering temperature is at 260°C for 10 seconds. Avoid overheating the sensor pins for a long time.

    B. All flux must be washed off after soldering and rinsed with a brush. Using an ultrasonic cleaner may cause performance problems.


    4.Product use restrictions


    Use and sell under any applicable law or regulation.


    Incorrect handling or storage due to incorrect use of the sensor is not the responsibility of the manufacturer.


    Quality TO-46 Package IR Infrared Thermopile Temperature Sensor 100K 3950 ISB-TS45H For Contactless Temperature Measurement wholesale
    Send your message to this supplier
     
    *From:
    *To: Aolittel Technology Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0