Categories | Stand-alond fire alarms |
---|---|
Brand Name: | ATL |
Model Number: | GA543 |
Certification: | CE.EN |
Place of Origin: | China |
MOQ: | 1 |
Price: | Sent on request |
Payment Terms: | T/T |
Supply Ability: | 10K PCS/month |
Delivery Time: | 5-10 workdays |
Packaging Details: | carton |
Company Info. |
Angel technologies Hongkong Ltd. |
View Contact Details |
Product List |
Product Overview
The gas detector is designed for single station use or for
connecting to fire alarm or security alarm panel. Small and
compact, the design and color makes it ideal for use in the home,
small commercial properties, and recreational vehicles. It is
intended to detect leakage of natural gas (methane gas), town gas,
and bottled gas (propane gas), coal gas.
While detecting the gas leaking reach the alarm level, the Red
Alarm LED would turn on and the buzzer sound urgently, while the
unit will output alarm signals, the unit´s relay activated and
output relay contacts.
The unit is designed for wire-in applications. The gas detector can
be mounted high (for methane gas) or low (for propane (LPG) gas).
It is equipped with a sturdy mounting base for quick, easy, and
secure installation.
Features
1. Detect all sorts of combustible gases, natural gas (methane),
bottled gas (propane), LPG (Liquefied petroleum Gas), LNG
(Liquefied natural gas), coal gas, including town gas. Wide Power
Input Range - DC9V-28VDC Easy to install, mounting bracket
included.
2. Loud 85dB alarm and LED warning light.
3. High quality durable sensor.
4. Self diagnostic function by MCU intelligent software.
5. Excellent reliability & High stability.
6. Ideal for all kitchens.
7. Test/Reset/Silence Button - Tests the alarm electronics and
resets or silence the unit during alarm.
8. Power LED - Red LED flashes every 5 seconds indicates detector
is receiving power and operating properly.
9. Alarm/Fault LED - Illuminates when in alarm (red) /fault
(yellow) mode.
10.Alarm Signal Output - Relay contacts outputs when in alarm mode
Technical Specifications
1. Power Source: DC9-28
2. Power Consumption: <3W(Standby), <5W(Alarm)
3. Sensitivity: LNG 5000ppm (10%LEL )
4. Audio Alarm: 85dB at 10ft ( 3meters )
5. LED: Red Flash(5s), Normal; Red Stead, Alarm; Yellow, Fault;
6. Relay Output: NO/NC(2A@24VDC); default setting is NO
7. Temperature Range: -10°C to 50°C
8. Humidity Range: 5%-95% relative humidity (RH)
9. Size: 99mm Diameter x 48mm Height
10.Weight: 165g
Dimensions
Ordering Information