Low Noise Tri-Lobe Roots Blower , Traditional Water Cooling Air Roots Blowers

Categories Tri-lobe Roots Blower
Brand Name: Purescience
Model Number: THW
Certification: ISO9001/SGS
Place of Origin: China
MOQ: 1
Price: USD2000
Payment Terms: L/C, T/T, D/P
Delivery Time: 2-3 weeks
Packaging Details: wooden case
Model: THW80
Product name: Roots air blower
Port size: DN80 - DN300
Silencer: Horizontal , vertical
Connect: coupling , belt
Material: cast iron
Pressure rating: 19.6kpa to 98.0 kpa ( 2000mm H2O to 10000mm H2O )
Cooling: water cooling
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Low Noise Tri-Lobe Roots Blower , Traditional Water Cooling Air Roots Blowers

    Water cooled Roots air blower | vacuum pump Cast iron inlet | outlet DN80 Cast iron for high pressure booster


    Goods Description

    The traditional water-cooling air roots blowers, the cog wheels can only be partly cooled, which may cause over-heat, hence break down possibly. Our new design THW series blower has the special feature, the main air room can be completely covered by the cooling water, the machine can withstand higher heat in this way, particularly in high pressure conveyance and the puffing air. Our rotor is made by the most advanced one time work process Four-Shaft method in order to reduce man-made errors, enhance the precision of the leave wheel, and to promote the blower efficiently.

    And the flange and groove rim of the air compartment and the side cover of our blower can not only reinforce the blower's operational functions but also keep eccentric phenomenal resulting from the fastening of the stud, which may reduce the blower life. Also, low Noise and Minimal Vibration are also the main features of our blowers. In addition, the special design for reducing the body temperature by using water between the body, and the casing and the Separate lateral chambers that designed for housing the moving parts with proper seals to prevent oil leakage are also earned our customer’s appreciation.


    Features

    • Lower noise:Pressure pluses are the major noise source in blowers. The Trundean roots blower design can efficiently reduce noise by approximately 5 dB.
    • Lower energy consumption:Trundean roots blower are designed to control backflow pressure to the rotor in order to reduce energy consumption.
    • Longer bearing life:Less vibration transmitted through the lobe results approximately 20% longer bearing life.

    Main technical data

    • Applications of the Pressure Conveyance
    • Pressures Applied:0 ~ 1 kgf/cm² 15 ~ 300HP
    • Special order with specific designs

    Specifications sheet


    ModelR.P.MCapacity Qs(m³/min) Pressure(mmAq) Power La(Kw)Cooling Water's Capacity
    6000mmAq7000mmAq8000mmAq9000mmAq10000mmAqL/min
    QsLaQsLaQsLaQsLaQsLa
    THW8011503.617.13.418.23.189.22.9510.52.7511.48
    13004.5184.39.24.0810.43.8411.63.6512.88
    14505.4195.210.34.9811.64.64134.4414.38
    16006.39.96.0911.45.8712.85.4314.35.3315.98
    17507.210.86.9912.46.77146.3315.66.2317.28
    THW10011505.5210.15.1611.64.9213.13.9212.63.7614.110
    13007.3111.4713.16.7914.86.4316.56.2718.210
    14508.5712.78.2514.68.0416.57.8618.47.5120.310
    16009.8214.19.5116.29.318.28.9420.48.7822.310
    17501115.410.717.710.519.910.222.310.12410
    THW125A97010.618.510.121.49.824.29.127.18.929.915
    115013.82213.325.41328.712.332.212.135.415
    130016.524.81628.715.632.41536.414.84015
    145019.127.718.63218.336.217.640.616.544.715
    160021.830.621.335.320.939.920.344.720.149.215
    THW150A85016.126.71628.215.731.814.243.713.643.218
    100020.331.420.133.419.837.718.44617.950.918
    115024.536.123.637.823.242.622.752.922.158.518
    125027.339.32742.126.747.525.557.524.963.618
    140031.64430.446.530.152.529.764.429.171.318
    THW20085022.934.622.339.721.745.12150.220.655.620
    95026.738.726.144.425.550.524.856.224.462.320
    105030.542.829.949.129.355.928.662.228.26920
    115034.246.833.653.833.161.232.368.13275.620
    12503850.937.458.536.966.636.174.135.882.320
    THW25085037.152.336.260.335.368.634.57733.68525
    95042.958.44267.441.176.740.38639.49525
    105048.764.547.874.546.984.846.19545.210525
    115054.470.653.581.652.692.851.810450.911525
    125060.276.759.388.758.410157.611356.712525
    THW300A65064.897.863.212361.8139.260.4156.459173.635
    73075.3118.573.713872.4156.470.917669.6185.235
    80084.513082.9150.781.5171.480.2192.178.9212.835
    88095.1143.893.5165.692.1188.690.8211.689.5234.635
    980108.1159.9106.6185.2105.2210.5103.9235.8102.6261.135

    Model selection


    1. The air volume shown in above performance form, it's the suction volume under standard suction condition (Temp. 20 ℃, absolute pressure 1.0332 kg/c㎡, relative humidity 65%).

    2. The convert formula between normal (for example: 0 ℃, 1.0332 kg/c㎡, ABS) and standard condition:

    Qs=Qn * (yn/ys), y=0.465 * (P-0.378 ᵩ * Ps) / (273+t)

    ᵩ=humidity (%) P=Pressure (mmHg)

    Qn: air flow under normal condition N m³/min

    Qs: air flow under standard condition (indicated in above performance table m³/min)

    Y: air ration weight (kg/m³)

    Ps: water vapor saturation pressure of the temperature (mmHg)

    T: absolute temperature (273+t) ℃

    3. Vice versa, an air flow under discharge condition can be converted to an air flow under standard condition:

    Qs=Qd * (1.0332+Pd) * (273 +Ts) / (1.032*(273+Td))

    Qd: air flow under discharge condition, m³/min

    Ts: suction temperature

    Td: discharge temperature

    Pd: discharge pressure, kgf/㎡

    4. Select blower type, diameter, rpm and shaft power based on performance table as required the air flow and discharge pressure.

    5. Smaller size for economic view, and larger size for lower noise level & stabler performance for a long view.


    Applications:


    Performance curve

    Product dimensions

    Applications:

    1. Air blowers / exhausters

    • PSA & VSA blowers and vacuum pumps
    • Off shore air scour blowers

    2. Corrosive / Toxic gases

    • Carbon dioxide blowers
    • SO2 gas blowers
    • VCM blowers

    3. Non corrosive gases

    • Hydrogen circulators
    • Nitrogen regeneration blowers
    • Stripping gas blowers
    • Conveying gas blowers

    4. Vacuum pumps

    • Multi stage vacuum pump skids
    • PSA & VSA blowers and vacuum pumps

    5. High pressure bossters

    6. Vapour boosters

    • LPG rail car
    • Tanker unloading compressor
    • Steam compressors
    • Vapour return boosters

    Competitive advantage

    All our tri-lobe roots blower are built and checked annually following the strictest adhesion to ISO 9001 and CE quality standards, involving the use of our highly precise and regularly maintained CNC machinery. Scrupulous attention is paid to every detail, in a specialized field where technical errors should be kept to a bare minimum.


    Quality Low Noise Tri-Lobe Roots Blower , Traditional Water Cooling Air Roots Blowers wholesale
    Send your message to this supplier
     
    *From:
    *To: Shanghai Xunhui Environment Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0